Fluke 1662 AU Multifunction Tester, 100 V, 250 V, 500 V, 1000 V
- RS Stock No.:
- 122-8555
- Mfr. Part No.:
- FLK-1662 AU
- Manufacturer:
- Fluke
View all Multifunction Testers
10 In stock for delivery within 1 working day(s)
Price (ex. GST) Each
$2,167.00
(exc. GST)
$2,383.70
(inc. GST)
units | Per unit |
1 + | $2,167.00 |
- RS Stock No.:
- 122-8555
- Mfr. Part No.:
- FLK-1662 AU
- Manufacturer:
- Fluke
RoHS Status: Not Applicable
- COO (Country of Origin):
- GB
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
- COO (Country of Origin):
- GB
Product Details
Fluke Multifunction Installation Testers
The Fluke 1660 series multifunction installation tester with an insulation test voltage of 100V, 250V, 500V, 1000V. It ensures safe and correct installation of fixed wiring to meet the necessary requirements. This tester is reliable and provides all the basic testing power you need for day-in, day-out installation testing. It is easy to use and tests all local regulations. The auto test feature reduces test time as it performs five required installation tests in one sequence, including selectable type A, AC, and RCD auto test. It reduces the number of manual connections, decreases the possibility of making errors, and reduces test time up to 40% from previous Fluke models.
Features and Benefits
Calculates prospective earth fault current (PEFC/IK) and prospective short-circuit current (PSC/IK)
Checks wiring polarity to detect broken N wires
Comes with a hard carrying case, padded carrying and waist strap and remote control probe and lead
Includes a phase sequence indicator
Measures insulation resistance and loop and line resistance
Measures motor windings with continuity test
Tests voltage and frequency
Measures RCD switching time and tripping level (ramp test)
Measures trip time and current for RCD type A & AC in one test
Measures RCD variable current
Provides automatic RCD test sequence
Includes Z-max memory for loop tests to support easy evaluation of the highest loop test value
Provides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation
Checks wiring polarity to detect broken N wires
Comes with a hard carrying case, padded carrying and waist strap and remote control probe and lead
Includes a phase sequence indicator
Measures insulation resistance and loop and line resistance
Measures motor windings with continuity test
Tests voltage and frequency
Measures RCD switching time and tripping level (ramp test)
Measures trip time and current for RCD type A & AC in one test
Measures RCD variable current
Provides automatic RCD test sequence
Includes Z-max memory for loop tests to support easy evaluation of the highest loop test value
Provides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation
Applications
Domestic
Industrial
Commercial
Industrial
Commercial
Certifications
CSA certified
CE certified
IP40 rated
EC/EN61557-1
IEC60364
IEC/EN61557-7
CE certified
IP40 rated
EC/EN61557-1
IEC60364
IEC/EN61557-7
Supplied with
6x AA (IEC LR6) cell batteries
C1600 hard carrying case
Zero adapter
Heavy duty mains cord
STD standard test lead set
C1600 hard carrying case
Padded carrying and waist strap
Quick reference guide
TP165X remote control probe and lead
C1600 hard carrying case
Zero adapter
Heavy duty mains cord
STD standard test lead set
C1600 hard carrying case
Padded carrying and waist strap
Quick reference guide
TP165X remote control probe and lead
Specifications
Attribute | Value |
Automatic RCD Test | Yes |
RCD Ramp Test | Yes |
Non-Tripping | Yes |
Insulation Test Voltage | 100 V, 250 V, 500 V, 1000 V |
Maximum Voltage Measurement | 500V ac/dc |
Test Type | Automatic RCD Test Sequence, Continuity, Continuity at L-N/N-PE Inputs, Earth Resistance, Frequency, Insulation at L-N/N-PE inputs, Insulation PreTest Safety function, Insulation Resistance, Loop & Line Resistance, Loop & Line Resistance-Resolution, Measure Motor Windings with Continuity Test, Measures Trip Time & Current for RCD Type A & AC in One Test, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short-Circuit Current, RCD Trip Current, RCD Trip Time, RCD Variable Current, Resistance, Test Smooth DC Sensitive RCDs, Voltage, Wiring Polarity Checker |
Continuity Test Current | 10mA |
Remote Switch Mode | Yes |
IP Rating | IP40 |
Length | 100mm |
Width | 250mm |
Power Source | Battery |
Height | 125mm |
Minimum Continuity Resistance | 20Ω |
Dimensions | 100 x 250 x 125mm |
Safety Category Level | CAT III, CAT IV |
Plug Type | Australia, New Zealand |
Safety Category Voltage | 300 V, 500 V |
Safety Category | CAT III 500 V, CAT IV 300 V |
Display Type | LCD |
Maximum Continuity Resistance | 2000Ω |
Weight | 1.3 (with Battery)kg |
Model Number p | 1662 AU |
Battery Type | AA |