CEAG Manual DOL Starter, 690 V ac, IP66

  • RS Stock No. 248-5166
  • Mfr. Part No. GHG6351101R0108
  • Manufacturer CEAG
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): DE
Product Details

Motor Starter

Single-phase failure via thermal electromagnetic trips are featured in these circuit breakers/manual motor starters. The respective switch position is clearly indicated by the switch handle. Terminals are protected against accidental contact. They have a terminal cross section of up to 10mm² for the connection of single or multi-wire conductors. The external contours of the enclosure allow easy access to the connection terminals and easy installation.

Connection terminals accessible from all sides
IP66 to EN60529 rating
Isolating properties to DIN EN 60947-3
690Vac upto 25A rating
Single phase failure protection
Padlocking facility via red button
Clear indication of switch position
268mm x 140mm x 150mm (H/W/D)

Note

Short-circuit protection up to 100kA and maximum back-up see 'key characteristics' table

//media.rs-online.com/t_line/L248508-01.gif
Specifications
Attribute Value
Motor Starter Type DOL
Voltage Rating 690 V ac
IP Rating IP66
Motor Starter Functionality Manual
Overall Length 225mm
Enclosure Yes
Overall Width 140mm
Overall Depth 156mm
Series GHG635
Hazardous Area Certification ATEX
Stock check temporarily unavailable - call for stock availability
Price (ex. GST) Each
Was $1,397.19
$ 1,266.72
(exc. GST)
$ 1,393.39
(inc. GST)
units
Per unit
1 +
$1,266.72
Related Products
LZ1H Series Professional range of Schneider Electric ultra-compact ...
Description:
LZ1H Series Professional range of Schneider Electric ultra-compact motor starter combinations from the LZ1H series The starters offer the best in class features needed for protection, safety monitoring and control of motor and power applications. Manual, electrical or automatic reset, ...
MS165 Series Manual Motor Starters ABB MS165 series ...
Description:
MS165 Series Manual Motor Starters ABB MS165 series manual motor starters are compact and powerful for motor protection The MS165 series features a clear indication of fault window to visible identification of short circuit tripping. Further features are a built-in ...
Standard Control Units Ideal to satisfy the basic ...
Description:
Standard Control Units Ideal to satisfy the basic protection requirements for motor starters; thermal overload and short-circuit Protection against overloads and short-circuits Protection against phase failure and phase imbalance Protection against insulation breaks (equipment protection only)Manual reset Class 10 ...
Te Sys Range DOL Starters, Non Reversing Schneider ...
Description:
Te Sys Range DOL Starters, Non Reversing Schneider Electrics non-reversing DOL (direct on line) starters form part of the fitted Te Sys range of components They are predominantly used for motor driving workshop machinery, large fans, water pumps and similar ...