Schneider Electric RCBO, 20A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type C, Acti9 Range, iC60 Range
- RS Stock No.:
- 654-789
- Mfr. Part No.:
- A9D19220
- Brand:
- Schneider Electric
Subtotal (1 unit)*
$835.26
(exc. GST)
$918.79
(inc. GST)
FREE delivery for orders over $60.00 ex GST
Stocked by manufacturer
- Ready to ship from 01 September 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
- RS Stock No.:
- 654-789
- Mfr. Part No.:
- A9D19220
- Brand:
- Schneider Electric
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | RCBO | |
| Current Rating | 20A | |
| Number of Poles | 2 | |
| Series | iC60 | |
| Range | Acti9 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Terminal Type | Screw Clamp | |
| Height | 110mm | |
| Depth | 72mm | |
| Width | 18mm | |
| Breaking Capacity | 10000A | |
| Application | Distribution | |
| Standards/Approvals | BS EN 61009-1, IEC 61009-1, IEC 61009-2-2 | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type RCBO | ||
Current Rating 20A | ||
Number of Poles 2 | ||
Series iC60 | ||
Range Acti9 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Terminal Type Screw Clamp | ||
Height 110mm | ||
Depth 72mm | ||
Width 18mm | ||
Breaking Capacity 10000A | ||
Application Distribution | ||
Standards/Approvals BS EN 61009-1, IEC 61009-1, IEC 61009-2-2 | ||
- COO (Country of Origin):
- TH
The Schneider Electric Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 2P circuit breaker with 1 protected pole, 20A In rated current and C tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with IEC 61009-1 and AS/NZS 61009.1 standards.
Device location in system is outgoer
Network frequency is 50 Hz
Network type is AC
Trip unit technology is thermal-magnetic
Related links
- Schneider Electric RCBO 2-Pole Type C iC60 Range
- Schneider Electric RCBO 3-Pole Curve C iC60 Range
- Schneider Electric RCBO 3-Pole Type C Acti9 iC60 Range
- ABB RCBO 2-Pole Type A 2CSR255163R Range
- Schneider Electric RCBO 4-Pole Type B A9d Range
- RS PRO RCBO 1-Pole Type B RCBO Range
- RS PRO RCBO 1-Pole Type C RCBO Range
- Schneider Electric Residential RCBO 1-Pole B Curve Acti9 iDPN