Subtotal (1 unit) $98.95(exc. GST)$98.95/unit | | True RMS | Clamp Meter | - | - | 600V ac | 600V dc | 20MΩ | - | RS330 | ±3% + 4 Digits | 1mA | ±1.5% + 2 Digits | 100V ac | AC/DC Clamp Meter | - | - | ±1.2 % rdg + 3 Digits | 100 V dc | 23mm | -10°C | ±3 % rdg + 5 Digits | - | - | 50°C | 205mm | 70mm | RoHS | 200g | 37mm | DC Voltage, AC Voltage, Diode, Resistance, AC Current, Continuity | - | - |
|
Subtotal (1 unit) $77.25(exc. GST)$77.25/unit | | - | Clamp Meter | - | 100mΩ | 600V ac | 600V dc | 400Ω | - | ICM3091N | ±2 % rdg + 10 Digits | 10mA | ±1.5 % rdg + 10 Digits | 100mV ac | AC Current Clamp Meter | ±1 % rdg + 2 Digits | - | ±1 % rdg + 5 Digits | 100 mV dc | 25.4mm | 0°C | ±1 % + 5 Digits | - | - | 40°C | 192mm | 64mm | IEC10101, RoHS Certificate of, IEC 10102032 | 250g | 31mm | Resistance, AC Current, DC Voltage, Continuity, AC Voltage | - | - |
|
Subtotal (1 unit) $337.51(exc. GST)$337.51/unit | | True RMS | Clamp Meter | 300A | - | 600V ac | - | - | - | ICMA1 | ±2.5% +5 Digits | 10mA | ±0.5 % rdg + 3 Digits | - | AC/DC Clamp Meter | ±1.5 % rdg + 5 Digits | 10mA | - | - | 25mm | 0°C | - | - | - | 50°C | 147mm | 60mm | EN610102032, EN613261, EN610101, EN610102030 | 140g | 31mm | Low Pass Filter, DC Current, AC Current, Inrush Current | - | - |
|
Subtotal (1 unit) $384.87(exc. GST)$384.87/unit | | True RMS | Clamp Meter | 1kA | 100mΩ | 1000V ac | 1000V dc | 100kΩ | - | IPM245F | ±1.5 % rdg + 5 Digits | 100mA | ±1 % rdg + 5 Digits | 100mV ac | Power Clamp Meter | ±1.5 % rdg + 5 Digits | 100mA | ±0.7 % rdg + 2 Digits | 100 mV dc | 27mm | 0°C | ±1 % + 3 Digits | ±1 % + 1 °C | 0.1°C | 50°C | 257mm | 87.5mm | IEC 610101, RoHS Certificate of | 470g | 50.5mm | Power Factor, DC Voltage, Frequency, DC Current, AC Current, Total Harmonic Distortion, Continuity, Temperature, Harmonics, AC Voltage, Diode, Power, Resistance, Capacitance | - | - |
|
Subtotal (1 unit) $262.75(exc. GST)$262.75/unit | | - | Clamp Meter | 400A | 40MΩ | 600V ac | 600V dc | 40mΩ | - | - | ±2.5 % rdg + 10 Digits | - | ±1.5 % rdg + 15 Digits | - | AC/DC Clamp Meter | ±2.5 % rdg + 10 Digits | 400A | ±(0.5%+8) / ±(1.5%+15) | 400 V dc | 32mm | 0°C | - | - | - | 40°C | 30mm | 175mm | EMC EN 613261, LVD EN 610101, EN 61010032, EN 61010031 | 148g | 60mm | Hz, AC, Ohm, DC (Mini- Size), DC Current, CAP, DC Voltage | - | - |
|
Subtotal (1 unit) $326.34(exc. GST)$326.34/unit | | True RMS | Clamp Meter | 80A | 100mΩ | 600V ac | 600V dc | 40MΩ | - | DT-338 | ±2.5 % | 1mA | ±2 % | 100V ac | DC Clamp Meter, Mini AC | ±2.5 % | 1mA | ±1.5 % rdg + 2 Digits | 100 V dc | 19mm | 5°C | ±1.5 % | ±2°C | 0.1°C | 40°C | 210mm | 70mm | No | 200g | 37mm | AC Voltage, AC Current, DC Current, Frequency, Duty Cycle, Continuity, Temperature, Capacitance, DC Voltage, Resistance, Diode | - | - |
|
Subtotal (1 unit) $334.57(exc. GST)$334.57/unit | | True RMS | Clamp Meter | 1mA dc | - | 999.99V ac | 1000V dc | 99.99kΩ | - | - | ±1.5 % rdg + 5 Digits | - | ±1 % rdg + 5 Digits | - | AC/DC Clamp Meter | ±1.7 % rdg + 2 Digits | - | ±0.7 % rdg + 2 Digits | - | - | 0°C | - | ± (1% + 2°F), ± (1% + 2°C) (-50°C-99.9°C), ± (1% + 1°C) (100°C-399.9°C, 400°C-1000°C), °F (212.0°F-751.9°F, 752°F-1832°F), ± (1% + 4°F) (-58°F-211.9°F) | - | 50°C | 242mm | 87.5mm | EN 613261, EN50419:2006, IEC 610101 | 435g | 50.5mm | Resistance, Total Harmonic Distortion, Power Factor, Power, Current, DC, Individual Harmonics, Temperature, Capacitance, Diode, Voltage, Frequency, Inrush Current, Continuity | - | - |
|
Subtotal (1 unit) $289.70(exc. GST)$289.70/unit | | True RMS | Clamp Meter | - | 100mΩ | 600V ac | 600V dc | 20MΩ | - | RS380 | ±2.5 % rdg + 5 Digits | 10mA | ±1.5% ± 10 Digits | 100V ac | AC/DC Clamp Meter | - | - | ±1.5 % rdg + 2 Digits | 100 V dc | 23mm | 5°C | ±1 % rdg + 4 Digits | ±(3.0% ±5°C) | 1°C | 40°C | 230mm | 82mm | RoHS | 230g | 40mm | AC Voltage, Temperature, Diode, Resistance, AC Current, Continuity, DC Voltage | - | - |
|
Subtotal (1 unit) $246.04(exc. GST)$246.04/unit | | True RMS | Clamp Meter | - | 100mΩ | 999V ac | 600V dc | 400Ω | - | ICM135R | ±1.9 % rdg + 5 Digits | 100mA | ±1 % rdg + 5 Digits | 100mV ac | Current, Voltage | ±1.9% + 5 Digits | - | ±0.7 % rdg + 2 Digits | 100 mV dc | 34mm | 0°C | ±1 % rdg + 3 Digits | - | - | 50°C | 220mm | 76mm | RoHS | 360g | 50mm | Frequency, Resistance, Continuity, Diode Test, AC Voltage, DC Voltage, AC Current | - | - |
|
Subtotal (1 unit) $397.61(exc. GST)$397.61/unit | | True RMS | Clamp Meter | 1000A | 40MΩ | 700V ac | 1000V dc | 40mΩ | - | - | ±3 % rdg + 8 Digits | - | ±1.2 % rdg + 5 Digits | - | AC/DC Clamp Meter | ±3 % rdg + 5 Digits | 1000A | ±0.8 % rdg + 5 Digits | 1000 V dc | 42mm | 0°C | - | - | - | 40°C | 28mm | 225mm | Safety LVD EN 610101, EN 61010032, EN 61010031, EMC EN 613261 | 260g | 82mm | DC with Bargraph, Hz, Ohm, AC | - | - |
|
Subtotal (1 unit) $199.19(exc. GST)$199.19/unit | | - | Clamp Meter | - | - | 999V ac | - | - | - | ICM20 | ±2 % rdg + 0.5A | 100mA | ±0.5 % rdg + 3 Digits | - | AC Current Clamp Meter | - | - | - | - | 27mm | 0°C | - | - | - | 50°C | 180mm | 56mm | RoHS | 250g | 32mm | Diode Test, Continuity, AC Current | - | - |
|
Subtotal (1 unit) $115.93(exc. GST)$115.93/unit | | - | Clamp Meter | - | - | 600V ac | 999.9V dc | 2kΩ | - | ICMA9 | ±1.8 % rdg + 3 Digits | 100mA | ±1.5 % rdg + 3 Digits | 100mV ac | AC Current Clamp Meter | - | - | ±1 % rdg + 2 Digits | 100 mV dc | 27mm | 0°C | ±2 % + 2 Digits | - | - | 50°C | 198mm | 66mm | MILT28800E, EN 613261, IEC 610101 | 260g | 46mm | AC Current, DC Voltage, Resistance, AC Voltage | - | - |
|
Subtotal (1 unit) $623.97(exc. GST)$623.97/unit | | - | Clamp Meter | - | 100mΩ | 400V ac | 100mV dc | 400Ω | - | ILCM03A | ±1 % rdg + 3 Digits | 10μA | ±1.5 % rdg + 2 Digits | 100mV ac | Current | - | - | - | 100 mV dc | 30mm | -10°C | ±1 % rdg + 2 Digits | - | - | 50°C | 210mm | 62mm | RoHS | 200g | 35.6mm | AC Current, Resistance, AC Voltage | - | - |
|
Subtotal (1 unit) $554.36(exc. GST)$554.36/unit | | True RMS | Clamp Meter | 600A | 100mΩ | 600V ac | 600V dc | 400Ω | - | ICM136R | ±1.9 % rdg + 5 Digits | 100mA | ±1 % rdg + 5 Digits | 100mV ac | Current, Voltage | ±1.9 % rdg + 5 Digits | 100mA | ±0.7 % rdg + 2 Digits | 100 mV dc | 35mm | 0°C | ±1 % rdg + 3 Digits | - | - | 50°C | 235mm | 78mm | EN 613261, IEC 610101, MILT28800E | 380g | 51mm | AC Voltage, Resistance, Frequency, Diode, Continuity, DC Current, AC Current, DC Voltage | - | - |
|
Subtotal (1 unit) $332.33(exc. GST)$332.33/unit | | True RMS | Clamp Meter | 1000A | 40MΩ | 1000V ac | 1000V dc | 40mΩ | - | - | ±3 % rdg + 8 Digits | - | 1.2 % | - | AC/DC Clamp Meter | 3 % | 1000A | 0.8 % | 1000 V dc | 42mm | 0°C | - | - | 1200°C | 40°C | 28mm | 225mm | EN 61326-1 | 260g | 82mm | AC, DC | - | - |
|
Subtotal (1 unit) $337.60(exc. GST)$337.60/unit | | - | Clamp Meter | - | 100mΩ | 250V ac | 600V dc | 30MΩ | - | IEK10N | ±1.9 % rdg + 0.5 A | 30mA | ±1.7% + 5 Digits | 1mV ac | AC Current Clamp Meter | - | - | ±0.7 % rdg + 2 Digits | 100 V dc | 29mm | 0°C | ±3 % rdg + 5 Digits | - | - | 50°C | 24mm | 145mm | IEC 1010-1 | 112g | 42mm | Continuity, Resistance, Diode, AC Voltage, AC Current, DC Voltage | - | - |
|
Subtotal (1 unit) $379.73(exc. GST)$379.73/unit | | True RMS | Clamp Meter | 600A dc | 100mΩ | 999V ac | 1000V dc | 20kΩ | - | IPM138N | ±1 % rdg + 5 Digits | 100mA | ±1 % rdg + 5 Digits | 100mV ac | Power Clamp Meter | ±1 % rdg + 5 Digits | 100mA | ±0.7 % rdg + 5 Digits | 100 mV dc | 35mm | 0°C | ±1% + 5 Digits | - | 0.1°C | 50°C | 235mm | 78mm | RoHS | 380g | 51mm | DC Current, Power Factor, Continuity, Resistance, AC Current, AC Voltage, Total Harmonic Distortion, Diode, Frequency, DC Voltage, Temperature, Wattage | - | - |
|
Subtotal (1 unit) $672.58(exc. GST)$672.58/unit | | True RMS | Clamp Meter | 1000A dc | 100mΩ | 750V ac | 1000V dc | 400Ω | - | ICM139R | ±1.9% +5 digits | 100mA | ±1 % rdg + 5 Digits | 100mV ac | Current, Voltage | ±1.9% + 5 Digits | 100mA | ±0.7 % rdg + 2 Digits | 100 mV dc | 51mm | 0°C | ±1 % rdg + 3 Digits | - | - | 50°C | 275mm | 90mm | IEC 610101, RoHS Certificate of | 420g | 51mm | Diode, Frequency, Continuity, Resistance, AC Voltage, AC Current, DC Current, DC Voltage | - | - |
|
Subtotal (1 unit) $392.78(exc. GST)$392.78/unit | | - | Clamp Meter | 4kA | - | 750V ac | 1000V dc | 40MΩ | - | ICM134 | ±1.9% +5 digits | 100mA | ±1.5 % rdg + 5 Digits | 1mV ac | HVAC Clamp Meter | ±1% + 2 Digits | - | ±0.9 % rdg + 2 Digits | 1 mV dc | 32mm | 0°C | ±0.7% + 2 Digits | -40.0°C → 0.0°C: 1% ± 4°C, 32°F → 750°F: 1% ± 6°F, 0.0°C → 400.0°C: 1% ± 3°C, 750°F → 1000°F: 2% ± 8°F °C, -40°F → 32°F: 1% ± 8°F | - | 50°C | - | - | IEC 610101:2001, EN 613261 | - | - | AC Voltage, DC Current, DC Voltage, Resistance, Diode, Capacitance, Temperature, AC Current, Continuity | - | - |
|
Subtotal (1 unit) $601.57(exc. GST)$601.57/unit | | True RMS | Clamp Meter | - | 100mΩ | 750V ac | 1000V dc | 400Ω | - | ICM133R | ±1.9% +5 digits | - | ±1 % rdg + 5 Digits | 100mV | Current, Voltage | ±1.9% + 5 Digits | - | ±0.7 % rdg + 2 Digits | - | 51mm | 0°C | ±1 % rdg + 3 Digits | - | - | 50°C | 275mm | 90mm | MILT28800E, IEC 610101, EN 613261 | 420g | 51mm | DC Voltage, Frequency, AC Voltage, Resistance, Diode, Continuity, AC Current | - | - |