Honeywell Technologies Pressure SensorBoard 6 DIP
- RS Stock No.:
- 203-6926
- Distrelec Article No.:
- 301-59-387
- Mfr. Part No.:
- ABPDRRV001PDSA3
- Brand:
- Honeywell
This image is representative of the product range
Bulk discount available
View bulk pricing optionsSubtotal (1 unit)*
$59.75
(exc. GST)
$65.72
(inc. GST)
FREE delivery for orders over $80.00 ex GST
In Stock
- Plus 65 unit(s) shipping from 28 September 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 - 24 | $59.75 |
| 25 - 49 | $58.29 |
| 50 + | $57.42 |
*price indicative
- RS Stock No.:
- 203-6926
- Distrelec Article No.:
- 301-59-387
- Mfr. Part No.:
- ABPDRRV001PDSA3
- Brand:
- Honeywell
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell | |
| Maximum Overload Pressure | 206kPa | |
| Sensor Type | Piezoresistive Pressure Sensor | |
| Product Type | Pressure Sensor | |
| Mount Type | Board | |
| Package Type | DIP | |
| Pin Count | 6 | |
| Minimum Supply Voltage | -0.3V | |
| Maximum Operating Pressure | 6.9 kPa | |
| Maximum Supply Voltage | 5V | |
| Port Type | Dual Radial Barbed | |
| Accuracy | ±0.25 % | |
| Maximum Operating Temperature | +85°C | |
| Series | ABP | |
| Width | 6.3mm | |
| Standards/Approvals | BPA Free, LFGB, NSF-169 | |
| Length | 7.3mm | |
| Height | 3.63mm | |
| Minimum Operating Pressure | 0psi | |
| Automotive Standard | ISO 9001 | |
| Minimum Operating Temperature | -40°C | |
| Select all | ||
|---|---|---|
Brand Honeywell | ||
Maximum Overload Pressure 206kPa | ||
Sensor Type Piezoresistive Pressure Sensor | ||
Product Type Pressure Sensor | ||
Mount Type Board | ||
Package Type DIP | ||
Pin Count 6 | ||
Minimum Supply Voltage -0.3V | ||
Maximum Operating Pressure 6.9 kPa | ||
Maximum Supply Voltage 5V | ||
Port Type Dual Radial Barbed | ||
Accuracy ±0.25 % | ||
Maximum Operating Temperature +85°C | ||
Series ABP | ||
Width 6.3mm | ||
Standards/Approvals BPA Free, LFGB, NSF-169 | ||
Length 7.3mm | ||
Height 3.63mm | ||
Minimum Operating Pressure 0psi | ||
Automotive Standard ISO 9001 | ||
Minimum Operating Temperature -40°C | ||
- COO (Country of Origin):
- CN
Honeywell ABP Series Differential Pressure Sensor, ±0.25% Accuracy, 6.9kPa Maximum Operating Pressure - ABPDRRV001PDSA3
This differential pressure sensor measures pressure differences between two ports and provides ratiometric analogue or 12‑bit digital output for real‑time monitoring in board‑mounted systems. It is temperature‑compensated and calibrated on an on‑board ASIC to correct for offset, sensitivity and temperature effects while updating outputs at up to 1kHz (analogue) or 2kHz (digital). The device is suitable for dry gases or, with a liquid media option, for non‑corrosive liquids and condensation environments.
Features and Benefits:
• ±0.25%FSS accuracy improves measurement confidence
• Total Error Band ±1.5%FSS limits worst-case error
• Operates from -40°C to +85°C for harsh conditions
• Sleep mode reduces power to 2μA for battery use
• I2C/SPI or ratiometric analogue outputs for design flexibility
• Liquid-media option enables wet/wet differential sensing
• Total Error Band ±1.5%FSS limits worst-case error
• Operates from -40°C to +85°C for harsh conditions
• Sleep mode reduces power to 2μA for battery use
• I2C/SPI or ratiometric analogue outputs for design flexibility
• Liquid-media option enables wet/wet differential sensing
Applications
• Suitable for CPAP and ventilator pressure monitoring
• Used with pneumatic control and valve positioning systems
• Ideal for coffee makers and domestic appliance pressure control
• Can be used for process gas monitoring in industrial plants
• Suitable for blood analysis and patient monitoring equipment
• Used with pneumatic control and valve positioning systems
• Ideal for coffee makers and domestic appliance pressure control
• Can be used for process gas monitoring in industrial plants
• Suitable for blood analysis and patient monitoring equipment
What media can be applied to the ports?
Dry gases are compatible by default and a silicone‑gel coated option permits non‑corrosive liquids and condensation exposure.
How does the device handle different supply voltages?
The output is ratiometric and scales with either a 3.3V or a 5.0V supply when the appropriate catalogue variant is selected.
What environmental extremes can it withstand?
It is specified to operate from −40°C to 85°C and survives vibration and shock levels shown in the environmental table.
What package and pin configuration are available for board mounting?
It is offered in DIP, SMT and leadless SMT packages with a six‑pin interface, analogue and digital pinouts are defined for GND, Vsupply and signal lines.
What certifications cover food‑contact safety?
Specific liquid‑option variants have been tested and certified to NSF‑169, LFGB and are BPA‑free.
Related links
- Honeywell ABPDRRV001PDSA3 Differential Pressure SensorThrough Hole 6 DIP
- Honeywell Differential Pressure SensorThrough Hole 6 DIP
- Honeywell HSCDRRV001PDAA5 Differential Pressure SensorThrough Hole 6 DIP
- Honeywell HSCDRRD005NDSA3 Differential Pressure SensorThrough Hole 6 DIP
- Honeywell HSCDRRV001PDSA3 Differential Pressure SensorThrough Hole 6 DIP
- Honeywell ABPDRRV001PDAA5 Differential Pressure SensorThrough Hole 6 DIP
- Honeywell HSCDRRD005NDAA5 Differential Pressure SensorThrough Hole 6 DIP
- Honeywell ABP2DRRN002ND2B3XX Differential Pressure SensorThrough Hole 6 DIP