Honeywell Technologies GLA Series Adjustable Roller Lever Limit Switch, 1 NC/1 NO, IP67, Die Cast Zinc Housing, 600V ac,
- RS Stock No.:
- 186-8251
- Distrelec Article No.:
- 136-30-806
- Mfr. Part No.:
- GLAC01A2B
- Brand:
- Honeywell Technologies
Subtotal (1 unit)*
$591.26
(exc. GST)
$650.39
(inc. GST)
FREE delivery for orders over $80.00 ex GST
- Plus 35 unit(s) shipping from 05 October 2026
Units | Per unit |
|---|---|
| 1 - 4 | $591.26 |
| 5 + | $486.61 |
*price indicative
- RS Stock No.:
- 186-8251
- Distrelec Article No.:
- 136-30-806
- Mfr. Part No.:
- GLAC01A2B
- Brand:
- Honeywell Technologies
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell Technologies | |
| Actuator Type | Adjustable Roller Lever | |
| Product Type | Limit Switch | |
| Contact Configuration | 1 NC/1 NO | |
| IP Rating | IP67 | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Terminal Type | M20 | |
| Switching Current | 6A | |
| Series | GLA | |
| Minimum Operating Temperature | -25°C | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 600V ac | |
| Maximum Operating Temperature | 85°C | |
| Depth | 42mm | |
| Standards/Approvals | CCC, CE, CSA, UL | |
| Width | 42mm | |
| Length | 145.8mm | |
| Hazardous Area Certification | No | |
| Operating Force | 0.33Nm | |
| Mechanical Life | 15000000Operations | |
| Conduit Entry | 20 mm | |
| Mounting Orientation | Side | |
| Select all | ||
|---|---|---|
Brand Honeywell Technologies | ||
Actuator Type Adjustable Roller Lever | ||
Product Type Limit Switch | ||
Contact Configuration 1 NC/1 NO | ||
IP Rating IP67 | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Terminal Type M20 | ||
Switching Current 6A | ||
Series GLA | ||
Minimum Operating Temperature -25°C | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 600V ac | ||
Maximum Operating Temperature 85°C | ||
Depth 42mm | ||
Standards/Approvals CCC, CE, CSA, UL | ||
Width 42mm | ||
Length 145.8mm | ||
Hazardous Area Certification No | ||
Operating Force 0.33Nm | ||
Mechanical Life 15000000Operations | ||
Conduit Entry 20 mm | ||
Mounting Orientation Side | ||
- COO (Country of Origin):
- GB



Honeywell GLA Series Limit Switch, 20mm Conduit Entry, 1 NC/1 NO Contact Configuration - GLAC01A2B
Features and Benefits:
• 1NC and 1NO contact arrangement offers flexible circuit options
• IP67 ingress protection enables use in wet or dusty locations
• Electrostatic epoxy-coated zinc housing resists corrosion in harsh sites
• Rated for 600V AC and 6A to handle common control voltages
• High mechanical life of 15,000,000 operations reduces replacement frequency
Applications
• Ideal for gate and valve position feedback in process plants
• Used with packaging machinery for stroke-limit monitoring
• Can be used for safety interlocks on machine guards
• Suitable for actuator position sensing in electrical switchgear
What actuator type does it use and how does that affect mounting?
How is electrical connection provided for conduit-based wiring?
What operating temperatures can it tolerate during continuous service?
What standards and approvals cover its safe adoption in installations?
How does the design support repetitive switching in high-cycle applications?
Approvals
Warning
Standards
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
Related links
- Honeywell GLA Series Adjustable Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Adjustable Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Adjustable Roller Lever Limit Switch IP67 600V ac, 10A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Adjustable Roller Lever Limit Switch IP67 600V ac,