SICK deTec2 Core Series Light Curtain Sender, 30 mm Resolution

Subtotal (1 unit)*

$1,304.35

(exc. GST)

$1,434.78

(inc. GST)

Add to Basket
Select or type quantity
Stock information currently inaccessible - Please check back later
Units
Per unit
1 +$1,304.35

*price indicative

RS Stock No.:
214-4296
Mfr. Part No.:
C2C-SA10530A10000
Brand:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Product Type

Light Curtain

Series

deTec2 Core

Beam Resolution

30mm

Component Type

Sender

Standards/Approvals

ACMA, CE, cUL, EC-Type-Examination, GB, GB/T, IEC, Moroccan, OSHA, RoHS, UKCA, cULus

Protective Height

1.05m

Maximum Supply Voltage

24V

Maximum Protective Width

15m

Maximum Scanning Distance

15m

Width

34mm

Maximum Response Time

11ms

Length

1.06m

Height

150mm

Terminal Type

5-Pin M12

COO (Country of Origin):
DE

SICK deTec2 Core Series Light Curtain, 1050mm Protective Height, 15m Maximum Scanning Distance - C2C-SA10530A10000


This light curtain is a safety sensor designed for industrial environments to protect personnel and machinery by detecting intrusions into a guarded area. It operates as a sender component within an optically synchronised system and is intended for normal industrial use with no blind zones. The unit accepts a 24V DC supply and communicates via a 5‑pin M12 plug interface, providing Visual status via LEDs and suited to installations requiring sealed enclosures and wide ambient tolerance.

Features and Benefits:


• 30mm beam resolution enables reliable object detection across the field
• 11ms response time supports Rapid detection and shutdown actions
• 15m protective width covers large machine safeguarding requirements
• IP65/IP67 enclosure rating permits use in harsh environments
• Aluminium extruded profile housing reduces weight while maintaining integrity

Applications


• Suitable for safeguarding conveyor transfer points in production lines
• Ideal for perimeter protection around automated machine tools
• Used for access control on robotic cells requiring optical synchronisation
• Can be used for safety zoning in material handling and packaging areas

What electrical connection is required for installation?


It connects via a 5‑pin M12 plug and runs from a 24V DC supply within a 19.2V to 28.8V range.

How does the unit behave when a fault occurs?


In a fault condition at least one output turns OFF to bring the system to a safe state.

Which environmental conditions can it tolerate during operation?


It operates between -30°C and +55°C with 15% to 95% non‑condensing humidity and resists vibration and shock per applicable standards.

What light characteristics does the sensor use for detection?


The device emits near‑infrared light at approximately 850nm Wavelength for invisible detection.