Schneider Electric 4 kW Automatic DOL Starter, 690 V ac, 3 Phase, IP657

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): FR
Product Details

TeSys Range DOL Starters, Non Reversing

Schneider Electrics non-reversing DOL (direct on line) starters form part of the fitted TeSys range of components. They are predominantly used for motor driving workshop machinery, large fans, water pumps and similar types of equipment.

Fitted TeSys range components
IP65 protection rating

Note

An overload relay must be fitted to each starter, before the starter will function typical stock no. 394-9431 .

Schneider Electric TeSys LE Enclosed DOL Starter - LE1D09P7

• Often referred to by the device short name LE1D
• Control type - Push-button start green "I" and the red stop reset pushbutton features the letter "O"
• Features a 9A AC-3 rated operational current
• The control circuit voltage is 230 V AC 50/60 Hz
• 9 A conventional enclosed thermal current
• Comprised of a strong polycarbonate material
• Dimensions - W88mm x H166mm x D128.5mm and weighs 0.92 kg
• IP65 Degree of protection

Specifications
Attribute Value
Power Rating 4 kW
Range TeSys
Motor Starter Type DOL
Voltage Rating 690 V ac
IP Rating IP657
Current Rating 9 A AC-3
Phase 3
Motor Starter Functionality Automatic
Reversibility No
Overall Length 166mm
Enclosure Yes
Overall Width 88mm
Overall Depth 128.5mm
Series LC1D
4 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 153.98
(exc. GST)
$ 169.38
(inc. GST)
units
Per unit
1 +
$153.98
Related Products
CONTACTRON '3 in 1' Hybrid Motor Starters Thanks ...
Description:
CONTACTRON '3 in 1' Hybrid Motor Starters Thanks to the internal interlocking circuit and load wiring, wiring expense in reduced to a minimum Contactron switches motors up to 4kW quickly and reliably. Forward running Motor protection Emergency stop75% less space ...
Standard Control Units Ideal to satisfy the basic ...
Description:
Standard Control Units Ideal to satisfy the basic protection requirements for motor starters; thermal overload and short-circuit Protection against overloads and short-circuits Protection against phase failure and phase imbalance Protection against insulation breaks (equipment protection only)Manual reset Class 10 ...
Motor Starter Single-phase failure via thermal electromagnetic trips ...
Description:
Motor Starter Single-phase failure via thermal electromagnetic trips are featured in these circuit breakers/manual motor starters The respective switch position is clearly indicated by the switch handle. Terminals are protected against accidental contact. They have a terminal cross section of ...
Single Phase Combination Motor Starters -GB2DB Range A ...
Description:
Single Phase Combination Motor Starters -GB2DB Range A combination unit consisting of a circuit breaker and a 2-pole contactorDIN rail mounting Breaking capacity 3kAContactor coils compatible with PLC inputs Ideal for starting single phase motors, except stock nos 351-5088, 351-5094, ...