United Automation AFM11, Universal Phase Angle Trigger Module
- RS Stock No.:
- 489-3418
- Distrelec Article No.:
- 172-05-453
- Mfr. Part No.:
- AFM11
- Brand:
- United Automation
Bulk discount available
Subtotal (1 unit)*
$221.36
(exc. GST)
$243.50
(inc. GST)
FREE delivery for orders over $60.00 ex GST
In Stock
- 10 unit(s) ready to ship from another location
- Plus 20 unit(s) shipping from 06 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 - 9 | $221.36 |
| 10 - 49 | $210.29 |
| 50 - 99 | $199.76 |
| 100 - 499 | $189.77 |
| 500 + | $180.27 |
*price indicative
- RS Stock No.:
- 489-3418
- Distrelec Article No.:
- 172-05-453
- Mfr. Part No.:
- AFM11
- Brand:
- United Automation
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | United Automation | |
| Product Type | Universal Phase Angle Trigger Module | |
| Minimum Operating Temperature | 0°C | |
| Maximum Operating Temperature | 75°C | |
| Standards/Approvals | I.E.T. Regulations (BS7671), Low Voltage Directive (LVD), EMC Directive | |
| Series | AFM11 | |
| Automotive Standard | No | |
| Select all | ||
|---|---|---|
Brand United Automation | ||
Product Type Universal Phase Angle Trigger Module | ||
Minimum Operating Temperature 0°C | ||
Maximum Operating Temperature 75°C | ||
Standards/Approvals I.E.T. Regulations (BS7671), Low Voltage Directive (LVD), EMC Directive | ||
Series AFM11 | ||
Automotive Standard No | ||
- COO (Country of Origin):
- GB
Universal Phase Angle Trigger Module, AFM-11
Phase angle trigger module for resistive & inductive loads.
Single phase or phase-to-phase use
Fires triacs & thyristors up to 480V
Resistive & inductive, ac/dc loads
Adjustable soft-start
Adjustable current limit
Voltage control or 4-20mA current loop
Pulse train firing via remote power transformer
Low power consumption
Status indication
The number of complete mains cycles during fixed repeating periods (typically 1 to 10 seconds) is varied, thus altering the duty cycle or on-/off-time ratio. Trigger pulses coincide with the zero-crossing times of the mains supply thus ensuring no RFI is produced when using resistive loads.
Note
Power transformer NOT included
Related links
- United Automation FC11AL/2 26 A
- United Automation MAT, Thyristor Trigger Module
- United Automation FC11BL, Thyristor Trigger Module
- United Automation STOM-1, Thyristor Trigger Module
- United Automation FC11AL, Phase-Angle Firing Module
- United Automation PSR-25 25 A 250 A
- United Automation PAC-2 25 A 250 A
- United Automation A34512 0.075 A 1 A
