ETA 1A 1 Pole Thermal Magnetic Circuit Breaker, 80 V dc, 250 V ac 201

  • RS Stock No. 333-237
  • Mfr. Part No. 201-1A
  • Manufacturer ETA
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

DIN Rail Mount, 201 Series

Single-pole thermal/magnetic circuit breakers which may be housed in any of the modular DIN 43 880 enclosures (refer to the Enclosures Sections). The speed of operation together with the availability of low current ratings offer the possibility of finely tuned performance not achievable with other forms of protection.

Close tolerance overload characteristics for professional equipment/system protection
Twin button operation (black reset/red trip)
Trip-free/tease-free operation
Only 12·5mm wide (compared to standard MCBs 17·5mm)
Approved for 250V a.c./65V d.c. operation
IEC Classification M/TM
Breaking Capacity: 200A (up to 2A), 400A (3A and above)

Approvals

UL, CSA, VDE, Demko, ABS, BV, LRoS

//media.rs-online.com/t_line/L333221-01.gif

Thermal Magnetic Convertible

All CBEs have blade terminals and have an insulation resistance greater than 100MΩ (MegaOhms).

Specifications
Attribute Value
Current Rating 1A
Number of Poles 1
Width 80mm
Series 201
4 : Next working day (AU stock)
44 : 5 working days (Global stock)
Price (ex. GST) Each
$ 85.19
(exc. GST)
$ 93.71
(inc. GST)
units
Per unit
1 - 9
$85.19
10 - 24
$83.06
25 - 49
$80.87
50 - 99
$78.62
100 +
$76.63
Related Products
PCB, single hole mountingSub-miniature, double insulatedTrip free mechanismSlow ...
Description:
PCB, single hole mountingSub-miniature, double insulatedTrip free mechanismSlow response time (typically 30 seconds at twice nominal current rating) ideal for inductive/reactive loadsTypical life 5000 operations (0.5 to 3A)/1000 operations (4 and 5A) at twice nominal current ratingMainly for motors, transformers ...
Snap-in panel mountingBlade terminals DIN 46244-C 2.8-0.8Miniaturised design ...
Description:
Snap-in panel mountingBlade terminals DIN 46244-C 2.8-0.8Miniaturised design High speed tripping characteristics (typically less than one second at twice nominal current rating)Typical life 300 operations at twice nominal current ratingMainly for domestic and industrial appliances, instrumentation, hand tools, ...
Front panel snap-in mounting, standard fuse holder cut-out ...
Description:
Front panel snap-in mounting, standard fuse holder cut-out dimensions6.3-0.8 blade terminalsSquare black pushbutton switch/circuit breakerTease free/trip free mechanism (typical response time 20 to 30 seconds at twice nominal current rating)Visual indication in tripped/off positionTypical life 300 operations at ...
All CBEs have blade terminals and have an ...
Description:
All CBEs have blade terminals and have an insulation resistance greater than 100MΩ (MegaOhms). 1-pole operation1 N/O + 1 N/C auxiliary contacts, for signalling purposesManual reset, tease-free, trip-free mechanismPull, manual release functionSmall physical sizeDelayed overload characteristics20 - 30 second ...