Fluke 87V 87V Handheld Digital Multimeter True RMS, 10 A, 10 A, 1000 V

This image is representative of the product range

Subtotal (1 unit)*

$1,218.00

(exc. GST)

$1,339.80

(inc. GST)

Add to Basket
Select or type quantity
Stock information currently inaccessible - Please check back later
Units
Per unit
1 +$1,218.00

*price indicative

RS Stock No.:
480-2355
Distrelec Article No.:
176-08-755
Mfr. Part No.:
FLUKE-87-V/CN
Brand:
Fluke
Find similar products by selecting one or more attributes.
Select all

Brand

Fluke

Multimeter Type

Handheld

Product Type

Multimeter

Resistance Resolution

100mΩ

Model Number

87V

Display Type

Digital

Functions Measured

AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance, Temperature

Maximum DC Current Measurement

10A

Maximum DC Voltage Measurement

1kV dc

Maximum AC Voltage Measurement

1000V

Maximum AC Current Measurement

10A

Maximum Resistance Measurement

50mΩ

True RMS

Yes

DC Current Accuracy

±0.2 % rdg + 2 Digits

AC Current Accuracy

±1 % rdg + 2 Digits

AC Voltage Accuracy

±2 % rdg + 4 Digits

DC Voltage Accuracy

±0.05 % rdg + 1 Digits

DC Voltage Resolution

0.1 mV dc

DC Current Resolution

0.1μA dc

AC Current Resolution

0.1μA ac

AC Voltage Resolution

0.1mV ac

Maximum Frequency

20kHz

Power Source

Battery

Minimum Operating Temperature

-20°C

Resistance Measurement Accuracy

±1 % rdg + 3 Digits

Battery Life

400h

Maximum Operating Temperature

55°C

Height

31mm

Length

186mm

Weight

355g

Standards/Approvals

No

Series

87V

Safety Category Level

CAT III, CAT IV

Battery Type

Alkaline

Safety Category Voltage

1000V

RoHS Status: Exempt

COO (Country of Origin):
US

Fluke Multimeter, 1000V Maximum DC Voltage Measurement, 10A Maximum DC Current Measurement - FLUKE-87-V/CN


This multimeter is a handheld diagnostic instrument designed for electrical, electronic and mechanical professionals to measure voltage, current, resistance, capacitance, frequency and temperature in industrial settings. It provides true-RMS AC readings, high-resolution DC measurement and a wide measurement span to support maintenance, fault-finding and calibration tasks.

Features & Benefits


• True-RMS AC measurement for accurate non-sinusoidal waveforms
• DC voltage precision to ±0.05% for fine measurement tasks
• AC current range up to 10A with 20kHz frequency capability
• 1000V rating for high-voltage industrial systems
• Capacitance and resistance ranges to 9999μF and 50MΩ respectively
• Long battery life of around 400 h for extended field use

Applications


• Suitable for industrial motor drive diagnostics with non-sinusoidal loads
• Ideal for servicing power distribution up to 1000V systems
• Used for precision DC voltage checks in control cabinets
• Can be used for frequency and duty-cycle verification on inverters
• Suitable for component testing including capacitors and diodes

What measurement resolution is available for frequency counting?


Frequency measurement offers up to 19,999 counts with 0.01 Hz resolution in the low range and maintained accuracy to 200 kHz under specified conditions.

How does it perform when measuring temperature?


Temperature measurement spans −200 °C to +1090 °C with 0.1 °C resolution and an accuracy expressed as 1% Plus 10 counts, excluding probe error.

What overload protection exists for current inputs?


The milliamp/μA inputs use a fast fuse rated for high-energy interruptions while the A input is protected by an 11 A fast fuse for continuous and short-duration currents.

How repeatable are transient readings and spikes?


The instrument records fast events with a Peak response down to 250 μs and specified accuracy limits for transient durations across DC and AC functions.

Note

For Calibrated articles - Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %

Supplied with

TL75 test leads, AC175 alligator clips, yellow holster, 9V battery, temperature probe, user manual, operators guide