Merlin Gerin C60HC MCB1P, 16A Curve C, 415V AC, 10 kA Breaking Capacity
- RS Stock No.:
- 221-370
- Mfr. Part No.:
- C60HC116
- Brand:
- Merlin Gerin
This image is representative of the product range
Unavailable
RS will no longer stock this product.
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
$43.64
(exc. GST)
$48.00
(inc. GST)
- RS Stock No.:
- 221-370
- Mfr. Part No.:
- C60HC116
- Brand:
- Merlin Gerin
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Merlin Gerin | |
| Number of Poles | 1 | |
| Current Rating | 16A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 415V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Series | C60HC | |
| Width | 18mm | |
| Length | 81mm | |
| Depth | 76mm | |
| Select all | ||
|---|---|---|
Brand Merlin Gerin | ||
Number of Poles 1 | ||
Current Rating 16A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 415V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Series C60HC | ||
Width 18mm | ||
Length 81mm | ||
Depth 76mm | ||
RoHS Status: Not Applicable
C60HC, Type C
Type C characteristic offers short circuit response of 5-10 x normal rated current, making it ideal for circuits with higher inrush currents such as motor control and fluorescent lighting installations in industrial buildings where nuisance tripping might occur if a faster type was used.
Positive indicator of contact position via front switch lever
Terminal shields for single and double pole versions
Auxiliary Changeover Switch which can be used as an indicating or control device to monitor the ON or OFF position of the MCB
Operating temperature of -30°C to +60°C
Compliance with BS EN 60898
Module widths: 1 pole 18mm, 2 pole 36mm and 3 pole 54mm
Terminal Capacity: 1→20A 25mm2, 32→63A 35mm2
Terminal shields for single and double pole versions
Auxiliary Changeover Switch which can be used as an indicating or control device to monitor the ON or OFF position of the MCB
Operating temperature of -30°C to +60°C
Compliance with BS EN 60898
Module widths: 1 pole 18mm, 2 pole 36mm and 3 pole 54mm
Terminal Capacity: 1→20A 25mm2, 32→63A 35mm2
Standards
BS EN 60898
Merlin Gerin – MCBs
Miniature Circuit Breakers; Contact Position indicated by switch levers
Related links
- Eaton xEffect MCB 16A Curve C 60V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve C 48V DC, 10 kA Breaking Capacity
- Schneider Electric Multi9 M9F MCB 10A Curve C 125V DC, 10 kA Breaking Capacity
- Hager Hager NRN Circuit Breaker 16A Curve C 25 kA Breaking Capacity
- Schneider Electric Acti9 A9D MCB 16A Curve C 6 kA Breaking Capacity
- Hager Hager NRN Circuit Breaker 16A Curve C 25 kA Breaking Capacity
- Hager Hager NRN Circuit Breaker 16A Curve C 25 kA Breaking Capacity
- Hager Hager HMX Circuit Breaker 16A Curve C 50 kA Breaking Capacity

