RS PRO 30 kW 3P Star Delta Starter, 400 V ac, 3 Phase, IP65

  • RS Stock No. 725-5563
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): IT
Product Details

Enclosed Star-Delta Motor Starters

A range of enclosed Star-Delta motor starters which combine high performance and low cost. The range includes options with and without isolator and support for motors from 11 kW to 30 kW.

Moulded plastic case providing IP65 ingress protection
Compliant with standards IEC/EN 60947-1 and IEC/EN 60947-4-1
Operating temperature range -25 °C → +60 °C
Starting time up to 12s and a maximum of 30 operations per hour

Note

Each starter is supplied WITHOUT an overload. An appropriate overload must be selected from the RF38 series (for example stock no. 685-1309) and would normally be rated at 58% of the motor FLC.

Specifications
Attribute Value
Power Rating 30 kW
Motor Starter Type Star Delta
Voltage Rating 400 V ac
IP Rating IP65
Current Rating 32 → 38 A
Phase 3
Number of Poles 3P
Additional Features Disconnect Switch Not Included
Overall Length 220mm
Enclosure Yes
Overall Width 280mm
Overall Depth 170mm
Standards Met IEC/EN 60947-1, IEC/EN 60947-4-1, RoHS Compliant
On back order for despatch 19/12/2019, delivery within 5 working days from despatch date.
Price (ex. GST) Each
$ 553.30
(exc. GST)
$ 608.63
(inc. GST)
units
Per unit
1 +
$553.30
Related Products
Thanks to the internal interlocking circuit and load ...
Description:
Thanks to the internal interlocking circuit and load wiring, wiring expense in reduced to a minimum Contactron switches motors up to 4kW quickly and reliably. Forward running Motor protection Emergency stop75% less space required75% less wiring time10 times longer service ...
Ideal to satisfy the basic protection requirements for ...
Description:
Ideal to satisfy the basic protection requirements for motor starters; thermal overload and short-circuit Protection against overloads and short-circuits Protection against phase failure and phase imbalance Protection against insulation breaks (equipment protection only)Manual reset Class 10 for 3-phase motors.
Single-phase failure via thermal electromagnetic trips are featured ...
Description:
Single-phase failure via thermal electromagnetic trips are featured in these circuit breakers/manual motor starters The respective switch position is clearly indicated by the switch handle. Terminals are protected against accidental contact. They have a terminal cross section of up to ...
A combination unit consisting of a circuit breaker ...
Description:
A combination unit consisting of a circuit breaker and a 2-pole contactorDIN rail mounting Breaking capacity 3kAContactor coils compatible with PLC inputs Ideal for starting single phase motors, except stock nos 351-5088, 351-5094, 351-5101 and 351-7539 which are suitable for ...