Eaton 7.5 kW Automatic 3P DOL Starter, 400 V ac, IP55

  • RS Stock No. 528-7634
  • Mfr. Part No. XDP7,5/ST(400V50HZ)
  • Manufacturer Eaton
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): GB
Product Details

D.O.L - Steel Enclosure

IP55 sheet steel enclosed starter complete with isolator for DOL applications to comply with IEE Regulations, 16th Edition on Isolation and Switching. AC-3 rated triple pole contactor with IP20 terminals and triple pole AC-3 rated switch disconnector with IP20 terminals fitted as standard. The disconnector has provision for up to 3 padlocks. The mushroom headed 'Stop' pushbutton is IP65 with the 'Start' pushbutton having an IP65 flush operator, both have IP20 terminals. Manufactured using readily available Moeller components which comply with the following specifications: isolator: IEC 943-3, pushbuttons: IEC 947-5-1, contactor: IEC 947-4-1. The enclosure is pre-wired to accept the Moeller Z00 or ZB thermal overloads which offer single phasing sensitivity to IEC 947-4. DOL starters comprise of an enclosure, switch disconnector, stop and start pushbuttons and a contactor.

Overload relay is not supplied and must be ordered separately
Fitted with 4x20mm and 2x25mm knockouts
H184 x W184 x D184mm

Note

FLC figures quoted are maximum, other overload ratings can be used dependent on FLC rating.

Specifications
Attribute Value
Power Rating 7.5 kW
Motor Starter Type DOL
Voltage Rating 400 V ac
IP Rating IP55
Number of Poles 3P
Motor Starter Functionality Automatic
Additional Features Disconnect Switch Included
Overall Length 184mm
Enclosure Yes
Overall Width 184mm
Overall Depth 184mm
Series XDP
4 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 341.11
(exc. GST)
$ 375.22
(inc. GST)
units
Per unit
1 +
$341.11
Related Products
Single-phase failure via thermal electromagnetic trips are featured ...
Description:
Single-phase failure via thermal electromagnetic trips are featured in these circuit breakers/manual motor starters. The respective switch position is clearly indicated by the switch handle. Terminals are protected against accidental contact. They have a terminal cross section of up to ...
A combination unit consisting of a circuit breaker ...
Description:
A combination unit consisting of a circuit breaker and a 2-pole contactorDIN rail mountingBreaking capacity 3kAContactor coils compatible with PLC inputsIdeal for starting single phase motors, except stock nos. 351-5088, 351-5094, 351-5101 and 351-7539 which are suitable for AC1 heating/lighting ...
Covers motors up to 16A (7.5kW)Local isolatorProtects against ...
Description:
Covers motors up to 16A (7.5kW)Local isolatorProtects against overloads, short circuits, phase failure and faults in cabling or wiringThese Motor Starters can be used in conjunction with ABB Contactors, stock no. 445-0897 typicallyAccessories available from auxiliary/signal contacts to under voltage ...
Motor reverse starter in housingEasy assembly thanks to ...
Description:
Motor reverse starter in housingEasy assembly thanks to pre-wiringShort circuit, motor overload and device protectionReady for connection, no additional overload relay requiredWith undervoltage release moduleSwitch settings: Hand - 0 - AutomaticCam switch for On/OffLockable main / EMERGENCY-STOP switchIn-situ or ...