Honeywell CSN Series Closed Loop Current Sensor, 0 → 600A, 150mA output current

  • RS Stock No. 477-4749
  • Mfr. Part No. CSNS300F
  • Manufacturer Honeywell
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): CN
Product Details

CSNS300 Sensors

Flexible alternative to the current shunt or transformers for the isolated measurement of a.c. or d.c. currents. Based on the principle of Hall effect and null balance method.

Small footprint
Measures dc, ac and impulse currents
Large primary conductor hole
High accuracy
Typical applications include; variable speed drives, overcurrent protection, power supply systems, frequency converters, UPS, robotics, battery management systems and welding equipment

//media.rs-online.com/t_line/L477474-01.gif
Specifications
Attribute Value
Sensor Technology Closed Loop
Output Current Range 150mA
Nominal Current 0 → 600A
Supply Voltage 15 V
Sensor Type Hall Effect
Mounting Type Busbar, PCB Mount
Frequency Bandwidth DC to 150 kHz
Accuracy ±0.5 %
Bore Size 26mm
Minimum Operating Temperature -40°C
Series CSN
Maximum Operating Temperature +85°C
Depth 17.9mm
Height 61.2mm
Width 67.5mm
10 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 175.70
(exc. GST)
$ 193.27
(inc. GST)
units
Per unit
1 - 4
$175.70
5 - 9
$169.80
10 +
$167.09
Related Products
Measures d.c. and a.c. pulsed and complex currents ...
Description:
Measures d.c. and a.c. pulsed and complex currents with galvanic isolation.,The transducer is capable of measuring nominal currents of 5, 6, 8, 12 and 25A by the use of a set of primary connection pins with an output of 24mA ...
Current sensor for electronic measurement of AC, DC ...
Description:
Current sensor for electronic measurement of AC, DC and impulse currents.Galvanic insulation between primary and secondary circuits.Internal voltage rating: 2.5 V. Applications: motor control and power supply.
The Honeywell CNS series of closed loop Hall-effect ...
Description:
The Honeywell CNS series of closed loop Hall-effect current sensors utilise the null balance or zero magnetic flux feedback method to provide accurate and repeatable measurements. The devices produce an output current which can be converted to a voltage by ...
Compensated closed-loop Hall effect current transducers for the ...
Description:
Compensated closed-loop Hall effect current transducers for the measurement of continuous, alternating, pulsed and mixed currents. Excellent dynamic performanceGood linearity and low temperature driftGalvanic isolation between input and measuring circuitPCB mountingBody material plastic to UL 94-V0.