    Zener and galvanic barriers are two types of electrical protection devices used in hazardous or explosive environments to prevent the ignition of flammable gases, vapours, or dust. These barriers are commonly employed in industrial settings such as oil refineries, chemical plants, and mining operations.

    What are Zener Barriers?

    A Zener barrier is an intrinsically safe device used to limit electrical energy and prevent the transfer of excess voltage or current from the non-hazardous area to the hazardous area. It employs a Zener diode, which is a special type of diode that conducts electricity in reverse bias when the voltage across it exceeds a specific value known as the Zener voltage. By utilizing the Zener effect, these barriers regulate the energy entering the hazardous area below the level that could cause ignition. Zener barriers are commonly used to protect intrinsically safe circuits and devices, such as sensors, transmitters, and switches.

    What are Galvanic Barriers?

    A galvanic barrier, also known as an isolator or isolation barrier, is another type of protection device used in hazardous environments. It provides electrical isolation between the hazardous area and the non-hazardous area, preventing the flow of direct current (DC) or low-frequency alternating current (AC) while allowing the transmission of signals or data. Galvanic barriers utilize transformers or optocouplers to provide the necessary isolation. These barriers are commonly employed to protect instruments, control systems, and communication interfaces from potentially hazardous electrical faults, surges, or short circuits.

    What applications would you use Zener and Galvanic Barriers?

    Zener and galvanic barriers are commonly used in various applications where electrical circuits and equipment need to be protected in hazardous environments. Some of the applications where these barriers are utilized include:Process Control Systems: Zener and galvanic barriers are widely used in process control systems found in industries such as oil and gas, chemical manufacturing, and pharmaceuticals. They provide protection for sensors, transmitters, and other control devices located in hazardous areas, ensuring safe and reliable operation.Industrial Automation: In industrial automation applications, Zener and galvanic barriers are employed to protect programmable logic controllers (PLCs), distributed control systems (DCS), and other automation equipment. These barriers safeguard the communication interfaces and control signals between the hazardous and non-hazardous areas.Instrumentation and Measurement: Zener and galvanic barriers are crucial for protecting measurement and instrumentation equipment used in hazardous environments. This includes devices such as pressure transmitters, temperature sensors, level indicators, and flow meters. The barriers ensure accurate data acquisition and control without posing a risk of ignition.* Power Distribution: Zener and galvanic barriers play a role in hazardous area power distribution systems. They are used to isolate and protect electrical circuits that supply power to equipment located in potentially explosive atmospheres, preventing the transfer of excessive voltage or current.Communication and Networking: In hazardous environments, Zener and galvanic barriers are used to safeguard communication and networking equipment, such as fieldbus systems, Ethernet switches, and wireless devices. They protect against electrical faults and potential ignition sources that could occur during data transmission.

    194 Products showing for Zener & Galvanic Barriers

    Eaton
    1
    Intrinsic Safety Barrier
    Zener Barrier
    Analogue
    27V dc
    -
    ATEX
    -
    300Ω
    93mA
    +60°C
    -20°C
    28V dc
    93mA
    27 V dc
    MTL7700
    Endress+Hauser
    1
    Galvanic Barrier/Isolator
    Galvanic Barrier
    0/4 to 20 mA
    24V dc
    -
    SIL 2, Zone 2
    Current
    -
    -
    -
    -
    -
    -
    -
    -
    Endress+Hauser
    2
    Isolating Amplifier
    Galvanic Barrier
    Relay
    30V dc
    -
    SIL 2, Zone 2
    NAMUR Sensor, Switch
    -
    -
    -
    -
    -
    -
    -
    -
    Endress+Hauser
    1
    Amplifier
    Isolating Switching Amplifier
    Current
    -
    -
    ATEX, IECEx
    Current
    -
    -
    -
    -
    24V dc
    -
    -
    -
    Pepperl + Fuchs
    2
    Zener Barrier
    Zener Barrier
    -
    250V
    -
    ATEX
    -
    646Ω
    46mA
    +60°C
    -20°C
    27V dc
    46mA
    250 V
    -
    Eaton
    2
    Intrinsic Safety Barrier
    Zener Barrier
    -
    8.4V
    -
    ATEX
    -
    90Ω
    100mA
    +60°C
    -20°C
    14V dc
    100mA
    8.4 V
    MTL7700
    Eaton
    2
    Switch/Proximity Detector Interface
    Zener Barrier
    -
    6.7V dc
    -
    ATEX
    RTD, Thermocouple
    50Ω
    200mA
    +65°C
    -20°C
    10V dc
    200mA
    6.7 V dc
    MTL7700
    Endress+Hauser
    1
    Amplifier
    Isolating Switching Amplifier
    Current
    -
    -
    -
    Current
    -
    -
    -
    -
    24V dc
    -
    -
    -
    Endress+Hauser
    1
    Amplifier
    Galvanic Barrier
    -
    -
    -
    -
    NAMUR Sensor, Switch
    -
    -
    -
    -
    250V
    -
    -
    -
    Pepperl + Fuchs
    2
    Zener Barrier
    Zener Barrier
    -
    250V
    -
    ATEX
    -
    106Ω
    89mA
    +60°C
    -20°C
    7.7V ac
    89mA
    250 V
    -
    Eaton
    1
    Isolated Driver
    Galvanic Barrier
    Current
    28V
    -
    ATEX
    Current
    -
    93mA
    +60°C
    -20°C
    20 → 35V dc
    93mA
    28 V
    -
    Eaton
    1
    Intrinsic Safety Barrier
    Zener Barrier
    -
    35V dc
    -
    ATEX
    Current
    300Ω
    93mA
    +65°C
    -20°C
    28V dc
    93mA
    35 V dc
    -
    Eaton
    2
    Switch/Proximity Detector Interface
    Galvanic Barrier
    Relay
    10.5V
    -
    ATEX
    NAMUR Sensor, Switch
    -
    14mA
    +60°C
    -20°C
    20 → 35V dc
    14mA
    10.5 V
    MTL5500
    Eaton
    1
    Solenoid Driver
    Galvanic Barrier
    Current
    10.5V
    -
    ATEX
    Current
    -
    108mA
    +60°C
    -20°C
    20 → 35V dc
    108mA
    10.5 V
    MTL5500
    Turck
    2
    Analogue Input Isolator
    Galvanic Barrier
    Voltage
    250V
    -
    ATEX, IECEx
    Current, Voltage
    -
    -
    +70°C
    -25°C
    20 → 250V ac
    -
    250 V
    IM
    Phoenix Contact
    2
    Isolating Amplifier
    Galvanic Barrier
    Relay
    125 V dc, 253V ac
    -
    ATEX
    NAMUR Sensor, Switch
    -
    10.3mA
    +60°C
    -20°C
    19.2 → 30V dc
    10.3mA
    125 V dc, 253 V ac
    MACX MCR-EX-SL-2NAM
    Pepperl + Fuchs
    1
    Zener Barrier
    Zener Barrier
    -
    250V
    -
    ATEX
    -
    327Ω
    93mA
    +60°C
    -20°C
    26.9V dc
    93mA
    250 V
    -
    Eaton
    3
    Intrinsic Safety Barrier
    Zener Barrier
    -
    2.7V dc
    -
    ATEX
    RTD, Thermocouple
    10Ω
    300mA
    +65°C
    -20°C
    3V dc
    300mA
    2.7 V dc
    MTL7700
    Phoenix Contact
    1
    Repeater power supply
    Galvanic Barrier
    Current
    125 V dc, 253V ac
    HART
    ATEX
    Current
    600Ω
    130mA
    +60°C
    -20°C
    19.2 → 30V dc
    130mA
    125 V dc, 253 V ac
    MACX MCR-EX-SL-RPSSI
    JM CONCEPT
    2
    Isolated Converter
    Galvanic Barrier
    Current
    -
    -
    -
    Current
    -
    -
    +60°C
    -10°C
    22 → 240 V dc, 90 → 230V ac
    -
    -
    EOLIS 0030A2
    Results per page