2 Output Toroidal Transformer, 30VA, 2 x 9V ac

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CZ
Product Details

Open Style with Leads, 115/230Vac Primary 15VA to 1000VA

High quality open style toroidal transformers with twin 115Vac 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. Twin secondary windings may be connected in series or parallel or used independently.

Small size and low weight compared with traditional stacked lamination types
Extremely low level of radiated magnetic field
Very low induced noise (hum)
Very low iron loss
Double insulated primary leads
Supplied with mounting kit
100% electrical and flash tested

Approvals

UL506, EN61558

Supplied with

Full mounting kit

//media.rs-online.com/t_line/L257488-01.gif

Approvals

VDE 0551; VDE 0550; UL 506

Standards

EN61558; EN60950; EN60065; BS415

Warning

  • Under no circumstances should both ends of the fixing bolt simultaneously contact the metal chassis or framework as this would create a potentially dangerous 'shorted-turn'.
Specifications
Attribute Value
Primary Voltage Rating 115 V ac, 230 V ac
Secondary Voltage Rating 2 x 9V ac
Power Rating 30VA
Number of Outputs 2
Secondary Current 1.667A
Height 32mm
Weight 450g
Diameter 70mm
Dimensions 70 (Dia.) x 32mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Termination Type Leads
Maximum Temperature +40°C
63 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 43.77
(exc. GST)
$ 48.15
(inc. GST)
units
Per unit
1 - 9
$43.77
10 - 24
$42.23
25 - 49
$41.43
50 - 99
$40.57
100 +
$39.85
Related Products
ABT7PDU series transformers This range of covered (up ...
Description:
ABT7PDU series transformers This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double windingSecondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or ...
Control transformers, 1-phase, 4AM Series Use as power, ...
Description:
Control transformers, 1-phase, 4AM Series Use as power, safety or displacement transformers in accordance with the applicable EN norm High short-term performance Low switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main side Electrically ...
PCB Mount 230Vac Primary VC/VCM Series Single and ...
Description:
PCB Mount 230Vac Primary VC/VCM Series Single and twin secondary windings for series or parallel connection Vacuum resin moulded to UL94-V0 rating Low inter-winding capacitance Low radiated noise100% electrical and flash tested Extra fixing points for secure board mounting (25 ...
Description:
Type UI 39 - 10 VA → 30 VA Secondary voltages are nominal load voltages on resistive loadsOnly the pins indicated on the wiring diagram "physically" exist. Standards IEC 742, VDE 0551, SEV 1003 Approvals UL 506. Secondary voltages are ...