Crouzet Temperature to Voltage Signal Conditioner, Temperature -40 → 40 °C Input, 0 → 10 V Output

  • RS Stock No. 509-1023
  • Mfr. Part No. 88950151
  • Manufacturer Crouzet
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): BG
Product Details

Millenium 2+ temperature converters

Millenium 2+ range of temperature converters that deliver an analogue signal of 0 → 10 Volts, fully compatible with Millenium inputs.
Various input ranges Pt100 / J and K thermocouples and temperature range.
3-wire input.
17.5 mm modular housing, DIN rail mounting.

Crouzet Millenium 2 Plus

Millenium 2 Plus has been designed to automate building and smaller machine applications. Many pre-programmed standard functions are available for counting, timing, comparison, multiplexing, time based programming, etc.,Non-expandable, expandable, and application specific starter kits are also available. All contain a Millenium II Plus unit, programming software on CD ROM, and serial (9-way D) PC to Millenium programming cable. The level control kit also includes four metal probes and a level sensor adaptor module. The HVAC kit also includes a 30W power supply, submersible -10°C to +150°C temperature probe and a 25A solid state relay with integral heatsink.

Application specific functions include pump rotation, cam timer, 8 value analogue store, PID, maths etc, in fact it will do virtually anything you want it to do!
Integrated calendar - clock, with up to 150 on/off cycles, programmable on date, day, week, month or year basis, with automatic summer/winter time change over
High-speed counter with 2 inputs on dc powered products; with max count speed of 4kHz
Two front panel buttons have user-definable functions and the remaining four allow parameter navigation and adjustment after the unit is programmed using software (stock no. 536-9203)
Programming software (stock no. 536-9203) is suitable for use with Windows 95, 98, 2000, NT4.0 SP5 and XP
LCD display with 4 lines of 12 characters and user controllable back light, can be used as small man-machine interface to display user defined messages or values
12Vdc, 24Vdc, 24Vac & 100-240Vac 50/60Hz models available, panel or DIN rail mounting
Expandable 20 I/O, and fixed 12 or 20 I/O versions available
Link two expandable units together using stock no. 444-5750
Water level control version of 12 I/O controller available which has four of the eight inputs dedicated to level control. Supplied with a 17.5mm wide level sensor adaptor module
Level control, HVAC and normal starter kits containing module, software and cable available
Program size 128 blocks, program memory: flash EEPROM, password protection
Data memory: 256 bits/64 words backed up for 10 years by lithium battery
Inputs: voltage discrete on/off (PNP on dc supply versions)
8 bit analogue inputs 0 to 10V (12 and 24Vdc versions) or 0 to 24V (24Vdc version only)
Outputs (isolated): N/O volt free relay contacts rated at 8A, one changeover output contact per module
Dimensions for Standard, Level Control and Expandable Units: H 90mm x W 72mm (12 I/O)/W 125mm (20 I/O) x D 60mm
Operating temperature range: -5 to +55°C

Specifications
Attribute Value
Input Range -40 → 40 °C
Output Range 0 → 10 V
Supply Voltage 24 V dc
Mounting Type DIN Rail
Minimum Operating Temperature -5°C
Maximum Operating Temperature +55°C
Operating Temperature Range -5 → +55 °C
14 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 128.90
(exc. GST)
$ 141.79
(inc. GST)
units
Per unit
1 +
$128.90
Related Products
Murrelektronik MU.W 6.2 Signal Conditioner Murr Elektronik MUW ...
Description:
Murrelektronik MU.W 6.2 Signal Conditioner Murr Elektronik MUW 6.2 series analog converters convert standard signal formats galvanically separated into a 4 mA to 20 mA signal. An integrated current limiter ensures the output is short-circuit and overload protected. Features and ...
IRMA - signal converter for PT100 Converts Pt100 ...
Description:
IRMA - signal converter for PT100 Converts Pt100 into standard signals Power supply from current loop or 9 → 32 Vdc Quickly adjusted via side-mounted DIP switches Wire breakage detection Converts Pt100 into standard signals Power supply from current loop ...
3RS170X Active Interface Converter Galvanic isolation of analogue ...
Description:
3RS170X Active Interface Converter Galvanic isolation of analogue signals Surge suppressor on analogue input2-way isolataion (output not isolated from supply)Yellow LED for visual voltage warning Galvanic isolation of analogue signals Surge suppressor on analogue input2-way isolataion (output not isolated from ...
Universal Signal Converter for Standard Signals 3-way isolation ...
Description:
Universal Signal Converter for Standard Signals 3-way isolation Configurable output signal in response to input signal interruption Short-circuit proof signal outputs prevents damage All units suitable for use within ambient temperature range from : -20 to +60°C. Module dimensions: H105 ...