Pilz Configurable 24 V dc Safety Relay Single Channel With 3 Safety Contacts and 1 Auxilary Contact

  • RS Stock No. 156-099
  • Mfr. Part No. 750102
  • Manufacturer Pilz
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

PNOZ Sigma Series 2 by PILZ

The PNOZ S2 series of Safety relay by PILZ. Known for their reliability and durability, PILZ safety relays offer you second to none safety protection features to ensure you and your workplace stay safe. Specifically, the S2 series is suitable for many different applications which you can find listed below.

Features and Benefits:

• LED display that offers you the following measures:
- Supply voltage
- Input status, channel 1
- Input status, channel 2
- Switch status, safety contacts
- Reset Circuit
- Error indication
• Operating mode can be set via rotary switches
• The S2 keeps safe separation of safety contacts from all your other circuits
• Plug in connection terminals
• 3 safety contacts N/O & 1 auxiliary contact N/C (both instantaneous)

Safety features

• Self-monitoring built in
• Safety functions remain effective in the case of components failure
• Correct opening and closing is tested automatically at the end of each on / off cycle
• The transform uses an electronic fuse which prevents short circuiting.

Applications

• E STOP pushbutton
• Safety gate limit switches
• Reset buttons

Technical safety parameters

• EN 60947-5-1
• EN 60204-1
• VDE 0113-1

How do Safety Relays work and what are they used for?

Safety Relays work by helping reduce unnecessary risk and hazard within your circuit. A typical circuit configuration may look like a production line where highly automated machinery works quickly, i.e. a production or packing line in a warehouse or factory. This line forms part of your 'circuit' and along that circuit you will have safety devices in place like emergency push buttons, safety curtains or pressure sensitive mats.
To ensure complete safety in these environments, a safety relay can be added to your circuit to allow you full control and monitoring of your working environment. A safety relay will run regular checks down your circuit by sending pulses back and forth to confirm whether any (for example) wiring was implemented incorrectly or any welding has occurred along the circuit. Once the relay has detected this, it would then shut down the area by cutting off the power, until the fault can be determined and fixed. Most recent safety relays feature intuitive LED displays that will alert users to any faults, this is of course useful to prevent harm to users and also proactively engage in maintenance before any machinery is damaged beyond repair, so certain cost savings can be associated when using a safety relay.
Some safety relays have specific functions and only work with certain devices like E-STOPs, some work better with other devices like safety curtains. More than one safety relay can be used to give you total monitoring of your circuit, ensuring you and your employees safety.

What are the differences between a traditional 'relay' and a 'safety relay'?

A traditional relay will open and close your circuit and the switch devices down that line, however it will not monitor it in the same way a safety relay will and cannot automatically shut down specified areas to prevent harm to the machinery or workers. Safety relays are not prone to the same potential risks that traditional relays are and can be relied upon to monitor short circuit faults, ground faults or wire breakage. Offering a greater protection over their counterpart relays, they are specifically designed with your safety in mind.

How do you operate a Safety Relay?

You must first align and wire the safety relay into your line and follow the setup instructions provided (will vary per manufacturer). Follow the onscreen instructions of the LED parallel to your instructions to perform integration into your circuit line. Depending on what parameters you set will determine the function of the safety relay (i.e. you tell it to cut off certain areas after certain criteria have been met, or you opt for a circuit wide halt of the line).

Standards

EN 60947-5-1, EN 60204-1 VDE 0113-1

Specifications
Attribute Value
Supply Voltage 24 V dc
Number of Channels 1
Auxiliary Contacts 1
Function Emergency Stop, Safety Switch/Interlock
Safety Contacts 3
Range PNOZsigma
Reset Method Automatic, Manual, Monitored
Terminal Type Screw
Length 102mm
Depth 120mm
Width 17.5mm
2 : Next working day (AU stock)
76 : 5 working days (Global stock)
Price (ex. GST) Each
$ 363.55
(exc. GST)
$ 399.91
(inc. GST)
units
Per unit
1 +
$363.55
Related Products
PZA/30, Fail Safe Monitor, On-delay DIN rail mounting ...
Description:
PZA/30, Fail Safe Monitor, On-delay DIN rail mounting For use with powered shot bolt applications Time delay selectable in 12 steps (3-30 secs)1 N/O safety contact, 2 N/C auxiliary contacts Feedback control loop for monitoring of external devices Standards VDE ...
PILZ P2HZ X1, Two Hand Monitoring, Type IIIC ...
Description:
PILZ P2HZ X1, Two Hand Monitoring, Type IIIC The P2HZ X1 series of Safety Relays by PILZ offer you affordable and reliable feedback control loops, specifically designed to handle the monitoring of your external relays or contactors Features and benefits ...
Emergency stop module, BD598702 / 001 Machine emergency ...
Description:
Emergency stop module, BD598702 / 001 Machine emergency stop switches Monitoring sliding grill guardsSK 4 (with equivalent switching)Output: 2 N/Os for AC 250 V1 or 2-channel configuration Line termination detection on the ON button Optional: cross-fault detection in the emergency ...
Standards EN61496-1 Type 2, and IEC 61496-2-Type 2 ...
Description:
Standards EN61496-1 Type 2, and IEC 61496-2-Type 2 and safety classification EN954-1 Category 3 The MFU Type 011160 from Smartscan offers you a reliable, smart and affordable safety relay. The type 011160 can be used in conjunction with the range ...