2 x 12V ac 2 Output Through Hole PCB Transformer, 2VA

  • RS Stock No. 173-9737
  • Mfr. Part No. 44129
  • Manufacturer Myrra
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): FR
Product Details

Type EI 30 - 1 VA → 2.3 VA series 44000 transformers

From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable.

Features and Benefits:

• Professional safety transformers with insulation above 4000V.
• For installation on printed circuit boards (according to European grid).
• Coupling in series or parallel.
• Vacuum-filled with resin to ensure materials withstand aging.
• Unit and 100% control on automated line.
• Secondary voltages are nominal load voltages on resistive loads.

Standards

UL 94-V0; VDE 0551; IEC 742

Approvals

UL, VDE

Encapsulated – Toroidal

Note

Fixing screws not provided

Specifications
Attribute Value
Secondary Voltage Rating 2 x 12V ac
Power Rating 2VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 32.6mm
Width 27.6mm
Depth 27.3mm
Dimensions 32.6 x 27.6 x 27.3mm
Weight 100g
Mounting Type Through Hole
Maximum Temperature +70°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
14 : Next working day (AU stock)
35 : 5 working days (Global stock)
Price (ex. GST) Each
$ 5.62
(exc. GST)
$ 6.18
(inc. GST)
units
Per unit
1 - 24
$5.62
25 - 49
$5.41
50 - 99
$5.22
100 - 249
$5.05
250 +
$4.91
Related Products
Thermal fuse in primary providing overload and short ...
Description:
Thermal fuse in primary providing overload and short circuit protection Flame retardant materials to UL94-V0Fully shrouded windings Extra pins for secure board mounting Designed and tested in accordance with EN 61558 (EN 60742) EN 60950
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loadsOnly the pins indicated on the wiring diagram "physically" exist.
Twin 115Vac. 50 to 60Hz primary windings for ...
Description:
Twin 115Vac. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins100% electrical and ...
230Vac. 50 to 60Hz primary Single or twin ...
Description:
230Vac. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have ...