2 x 12V ac 2 Output Through Hole PCB Transformer, 2VA

  • RS Stock No. 173-9737
  • Mfr. Part No. 44129
  • Manufacturer Myrra
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): FR
Product Details

Type EI 30 - 1 VA → 2.3 VA series 44000 transformers

From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable.

Features and Benefits:

• Professional safety transformers with insulation above 4000V.
• For installation on printed circuit boards (according to European grid).
• Coupling in series or parallel.
• Vacuum-filled with resin to ensure materials withstand aging.
• Unit and 100% control on automated line.
• Secondary voltages are nominal load voltages on resistive loads.

Standards

UL 94-V0; VDE 0551; IEC 742

Approvals

UL, VDE

Encapsulated – Toroidal

Maximum Operating Temperature +60°C
Primary – Secondary Test Voltage 4 kV
UL Recognised for Insulation Class A +105°C
Meets All Requirements of Class E +120°C
Pin Length x Diameter 1 x 0.5 mm

Note

Fixing screws not provided

Specifications
Attribute Value
Secondary Voltage Rating 2 x 12V ac
Power Rating 2VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 32.6mm
Width 27.6mm
Depth 27.3mm
Dimensions 32.6 x 27.6 x 27.3mm
Weight 100g
Mounting Type Through Hole
Maximum Temperature +70°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
6 : Next working day (AU stock)
43 : 5 working days (Global stock)
Price (ex. GST) Each
$ 5.67
(exc. GST)
$ 6.24
(inc. GST)
units
Per unit
1 - 24
$5.67
25 - 49
$5.46
50 - 99
$5.27
100 - 249
$5.09
250 +
$4.95
Related Products
PCB mounting mains transformers with a single 230Va.c. ...
Description:
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Fully shrouded bobbinsExtra pins for ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...