9V ac 2 Output Through Hole PCB Transformer, 6VA

  • RS Stock No. 504-414
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

PCB Mounting, Flame Retardant Transformer with Thermal Fuse

Thermal fuse in primary providing overload and short circuit protectionFlame retardant materials to UL94-V0Fully shrouded windingsExtra pins for secure board mountingDesigned and tested in accordance with EN 61558 (EN 60742) EN 60950

//media.rs-online.com/t_line/L805502-01.gif

Approvals

8888

Standards

EN 61558 (EN 60742); EN 60950

Open Frame - Laminated

PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section metric bobbin constructionFull varnish impregnation

Specifications
Attribute Value
Secondary Voltage Rating 9V ac
Power Rating 6VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 43mm
Width 36mm
Depth 33mm
Dimensions 43 x 36 x 33mm
Weight 180g
Mounting Type Through Hole
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
41 In stock for delivery within 7 working day(s) (Global Stock)
Price (ex. GST) Each
$ 14.35
(exc. GST)
$ 15.79
(inc. GST)
units
Per unit
1 - 9
$14.35
10 - 24
$14.11
25 - 49
$13.59
50 - 99
$13.30
100 +
$13.06
Related Products
ABT7ESM0 series economic transformer This range of single-phase ...
Description:
ABT7ESM0 series economic transformer This range of single-phase single-winding safety and isolation transformer is primarily designed for use in repetitive applicationsABT 7 series transformers provide enhanced electrical isolation between the mains supply and the application. The whole range features an ...
ABL 6TS safety transformers Single-phase single-winding safety and ...
Description:
ABL 6TS safety transformers Single-phase single-winding safety and isolation transformersAble to supply higher powers on occasion.Feature a panel display to reduce ESD. Screw termination.Plate mounting. Standards IEC 61558-2-6 , EN61558-2-6. Chassis mounting frame construction low voltage mains transformers with a ...
PCB Mount 230Vac Primary VC/VCM Series Single and ...
Description:
PCB Mount 230Vac Primary VC/VCM Series Single and twin secondary windings for series or parallel connection Vacuum resin moulded to UL94-V0 rating Low inter-winding capacitance Low radiated noise100% electrical and flash tested Extra fixing points for secure board mounting (25 ...
Description:
Type UI 39 - 10 VA → 30 VA Secondary voltages are nominal load voltages on resistive loadsOnly the pins indicated on the wiring diagram "physically" exist. Standards IEC 742, VDE 0551, SEV 1003 Approvals UL 506. Secondary voltages are ...