RS PRO 300VA Isolating Transformer, 230 V ac, 245 V ac, 400 V ac, 415 V ac Primary 1 x, ±12V ac Secondary

  • RS Stock No. 504-149
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

Control Panel Primary 230/ 400Vac with +15Vac Tap

High quality safety and isolating transformers designed for use in control circuits and general applications
Low loss noise laminations
Dual standard primary winding 230 / 400Vac with +15V tap for input flexibility
Dual secondaries are centre tapped. Earth terminal provided
Varnish impregnated for overall protection against humidity and rusting
Fully shrouded cage clamp terminal with voltage markings
Detailed product specification on permanent label
High efficiency, low regulation design

Approvals

8888

Standards

BS EN 61558

Laminated

Specifications
Attribute Value
Primary Voltage Rating 230 V ac, 245 V ac, 400 V ac, 415 V ac
Secondary Voltage Rating ±12V ac
Power Rating 300VA
Mounting Type DIN Rail
Number of Outputs 1
Length 120mm
Width 143mm
Depth 130mm
Dimensions 120 x 143 x 130mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Maximum Temperature +35°C
Weight 6.9kg
23 In stock for delivery within 7 working day(s) (Global Stock)
Price (ex. GST) Each
$ 196.99
(exc. GST)
$ 216.69
(inc. GST)
units
Per unit
1 - 9
$196.99
10 - 24
$191.29
25 - 49
$183.64
50 - 99
$176.99
100 +
$172.04
Related Products
Control Panel Primary 230/400Vac (310 to 1000VA) Compact, ...
Description:
Control Panel Primary 230/400Vac (310 to 1000VA) Compact, open type control panel transformer Fully shrouded screw terminals with permanent marking Detailed product specification permanently marked on front of unitVA ratings compatible with available protection devices Dual standard primary winding 230 ...
Control Panel Primary 230/400Vac with +15Vac Tap High ...
Description:
Control Panel Primary 230/400Vac with +15Vac Tap High quality safety and isolating transformers designed for use in control circuits and general applications Low loss noise laminations Dual standard primary winding 230 / 400Vac with +15V tap for input flexibility Dual ...
Control Panel Primary 690Vac (63/2500VA) Low inrush current ...
Description:
Control Panel Primary 690Vac (63/2500VA) Low inrush current control, safety isolating and isolating transformer Screw type terminals, fitted with screw mounting brackets Compact design with ±20V tappings on the primary winding For use up to +40°C ambient maximum Low inrush ...
Description:
Type UI 39 - 10 VA → 30 VA Secondary voltages are nominal load voltages on resistive loadsOnly the pins indicated on the wiring diagram "physically" exist. Standards IEC 742, VDE 0551, SEV 1003 Approvals UL 506. Secondary voltages are ...