LEM CAS Series Closed Loop Current Sensor, 25A

  • RS Stock No. 666-8185
  • Mfr. Part No. CAS 25-NP
  • Manufacturer LEM
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

CAS/CASR/CKSR Series Current Transducers

This range has been designed to provide current measurements from 6 to 50Arms in a very compact size. Based on the Closed Loop Fluxgate technology for better accuracy.

Measurent of DC and AC current
PCB mounting
Low temperature drift

Standards

EN 50178

Specifications
Attribute Value
Sensor Technology Closed Loop
Nominal Current 25A
Supply Voltage 5.25 V
Mounting Type PCB Mount
Frequency Bandwidth 200 → 300 kHz
Accuracy ±0.8 %
Series CAS
Minimum Operating Temperature -40°C
Maximum Operating Temperature +85°C
Depth 13.4mm
Height 16.5mm
Width 21.91mm
37 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 16.98
(exc. GST)
$ 18.68
(inc. GST)
units
Per unit
1 - 5
$16.98
6 +
$16.82
Related Products
Linear current sensors from Honeywell incorporating LOHET II ...
Description:
Linear current sensors from Honeywell incorporating LOHET II Hall effect transducers These devices have increased temperature stability and 10 times less temperature drift than the LOHET I types and produce a ratiometric output voltage that varies from 19% to 81% ...
Passive current transformers without auxiliary power Convert ac ...
Description:
Passive current transformers without auxiliary power Convert ac into analogue signals 1 to 20mA or 0 to 10VLimit monitor Limit value and alarm suppression time set by two potentiometers1 NO, 1NC relay contact
Single-pole closed-loop current transducers based on the Hall ...
Description:
Single-pole closed-loop current transducers based on the Hall effect principle Voltage output3 different input ranges via selection pins Compact format for mounting on pc.b.Excellent precision and good linearity Low temperature drift Body material plastic to UL94-V0.
AC / DC transformer with integrated signal preparation ...
Description:
AC / DC transformer with integrated signal preparation Measures currents with VFD and SCR wavelength Electrical isolation Actual output; voltage or current No excess losses Cable entry to 32 mm ØSimple installation