| Schmersal | - | 100V ac/dc | - | Stainless Steel | 1m Cable | - | - | Coded | - | - | Magnetic | - | BNS40S | 18 (Off) mm, 8 (On) mm | IP69K | Maximum of 250mA | - |
|
| Schmersal | Actuator Included | - | - | Glass Fibre Reinforced Thermoplastic | - | - | - | Coded | - | - | Magnetic | BPS 260 | BPS 260 | - | IP67 | 400mA | - |
|
| Schmersal | - | 20.4 → 26.4V dc | - | Glass Fibre Reinforced Thermoplastic | - | - | - | Coded | - | - | - | - | RSS 260 | - | IP65, IP66, IP67 | 150mA | - |
|
| Schmersal | - | 24V dc | NC | Plastic | Cable | - | - | Coded | - | 4 | Magnetic | - | BNS300 | - | IP67 | 3A | - |
|
| Schmersal | - | 24V dc | NC | Plastic | M12 | - | - | Coded | - | 4 | Magnetic | - | BNS300 | - | IP67 | 30mA | - |
|
| Schmersal | - | - | - | 316 Stainless Steel | - | - | - | Magnetic | - | - | - | - | BPS | - | - | - | - |
|
| Schmersal | - | 24 V dc, 100 V ac/dc | NO/NC | Plastic | Cable | - | - | Coded | - | 4 | Magnetic | - | BNS33 | - | IP67 | 10mA | ATEX |
|
| Schmersal | - | - | - | Plastic | - | - | - | Coded | - | - | Magnetic | - | BPS 303 | - | - | - | - |
|
| Schmersal | - | 20.4 → 26.4V dc | - | Glass Fibre Reinforced Thermoplastic | M12 | Non-Flush | - | Coded | - | 3 | RFID | - | RSS 36 | 10 (On) mm, 12 mm, 20 (Off) mm | IP65, IP67, IP69K | 600mA | - |
|
| Schmersal | - | 24V ac/dc | - | Stainless Steel | 1m Cable | Non-Flush | - | Coded | - | - | Magnetic | - | EX-BNS40S | 18 (Off) mm, 8 (On) mm | IP65, IP67 | Maximum of 10mA | ATEX |
|
| Schmersal | - | 100V ac/dc | - | Plastic | M12 | - | - | Coded | - | 4 | Magnetic | - | BNS16 | 8 (ON) mm, 18 (OFF) mm | IP67 | - | - |
|
| Schmersal | - | 24V ac/dc | NO/NC | Stainless Steel | 1m Cable | Non-Flush | - | Coded | - | - | Magnetic | - | EX-BNS40S | 18 (Off) mm, 8 (On) mm | IP65, IP67 | Maximum of 250mA | ATEX |
|
| Schmersal | - | - | - | Plastic | - | - | - | Magnetic | - | - | - | - | - | - | - | - | - |
|
| Schmersal | - | - | 2NC | Glass Fibre Reinforced Thermoplastic | 5m Cable | Flush | Magnetic | - | - | - | Magnetic | - | BNS 36 | - | - | - | - |
|
| Schmersal | - | - | 2NC | Glass Fibre Reinforced Thermoplastic | 5m Cable | Flush | Magnetic | - | - | - | Magnetic | - | BNS 36 | - | - | - | - |
|
| Schmersal | - | - | 2NC | Glass Fibre Reinforced Thermoplastic | 5m Cable | Flush | Magnetic | - | - | - | Magnetic | - | BNS 36 | - | - | - | - |
|
| Schmersal | - | - | NO/2NC | Glass Fibre Reinforced Thermoplastic | 5m Cable | Flush | Magnetic | - | - | - | Magnetic | - | BNS 36 | - | - | - | - |
|
| Schmersal | - | - | NO/2NC | Glass Fibre Reinforced Thermoplastic | 5m Cable | Flush | Magnetic | - | - | - | Magnetic | - | BNS 36 | - | - | - | - |
|
| Schmersal | - | - | NO/NC | Glass Fibre Reinforced Thermoplastic | 5m Cable | Flush | Magnetic | - | - | - | Magnetic | - | BNS 36 | - | - | - | - |
|
| Schmersal | - | - | NO/NC | Glass Fibre Reinforced Thermoplastic | 5m Cable | Flush | Magnetic | - | - | - | Magnetic | - | BNS 36 | - | - | - | - |