Multifunctional Safety Module

  • RS Stock No. 181-2781
  • Mfr. Part No. UG6980.04PS/61 DC24V
  • Manufacturer Dold
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Line fault detection on On-button:
Manual restart or automatic restart
With or without cross fault monitoring
2-channel
Forcibly guided output contacts
Output: max. 4 NO instantaneous semiconductor monitoring output
LED indicator for operation, delay contacts and failure
As option with pluggable terminal blocks for easy exchange of devices
with screw terminals
or with cage clamp terminals
Width: 22.5 mm
Advantages / Customer benefit
Adjustable safety functions:
E-Stop
Safety gate
Two-hand control
Safety mat / Safety edge
Exclusive or contacts
Light curtain
Manual or auto start
Only one device, different safety functions
Protection against manipulation by seal able transparent cover

Specifications
Attribute Value
Supply Voltage 24 V dc
Number of Channels 2
Safety Contacts 4
Reset Method Auto Start, Manual
Safety Category PL e 4, SIL 3, 4
Terminal Type Screw
Length 22.5mm
Width 120.3mm
Depth 110mm
3 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 478.75
(exc. GST)
$ 526.63
(inc. GST)
units
Per unit
1 +
$478.75
Related Products
XY2 AU, Enabling Switch XPS-VC switches XY2AU used ...
Description:
XY2 AU, Enabling Switch XPS-VC switches XY2AU used in conjunction with the XPS-VC safety relay offer a certified safety solution ensuring the safety of machine operators during setting and maintenance operations Use while carrying out adjustment of moving parts Allows ...
Preventa Non-safe Fieldbus Communication Modules, XPSMCM The Preventa ...
Description:
Preventa Non-safe Fieldbus Communication Modules, XPSMCM The Preventa XPSMCM non-safe fieldbus communication modules are designed for diagnostic connection and data communication to machine field bus or network systems They have a compact designed, 22.5 x 99 x 114.5 mm, the ...
Preventa Non-safe Fieldbus Communication Modules, XPSMCM The Preventa ...
Description:
Preventa Non-safe Fieldbus Communication Modules, XPSMCM The Preventa XPSMCM non-safe fieldbus communication modules are designed for diagnostic connection and data communication to machine field bus or network systems They have a compact designed, 22.5 x 99 x 114.5 mm, the ...
G9SA, Safety Relays, Expandable The G9SA family offers ...
Description:
G9SA, Safety Relays, Expandable The G9SA family offers a line-up of compact and expandable safety relay units Modules with safe OFF-delay timing are available as well as a two hand controller. Simple multiplication of safety contacts is possible by using ...