E-Stop Rope Pull Switch, Left Side

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
Product Details

Telemecanique XY2CE & XY2CB Emergency Stop Rope Pull Switches

These emergency stop trip wire switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the trip wire breaking.

Switches incorporate positive opening operation contacts, the tripping of the switch being made with positive action
The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling
Incorporates a reset button, which re-closes the safety contact(s), restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the trip wire switch
Recommended distance between cable supports is 15m (for model XY2-CB30 a distance of 20m is recommended)
The XY2 CE1A296 comes with a pilot light (direct supply)

Note

The XY2 CB switch must not be used if the installation requires that the trip wire be angled but the XY2 CE switch can. In this case, the total sum of the angles through which the trip wire bends must not exceed 180°.

Standards

EN/ISO 13850:2006

Specifications
Attribute Value
Normal State Configuration NC, NO
Housing Material Stainless Steel (Cover), Zamak (Body)
Maximum AC Voltage 240V
Maximum DC Voltage 250V
Range Preventa XY2
Series XY2CE
Minimum Operating Temperature -25°C
Dimensions 229 x 105 x 142 mm
Depth 142mm
Width 105mm
Length 229mm
Standards Met CCC, CSA, CSA C 22-2, EAC, EN/IEC 60947-5-5, UL (NISD), UL 508
IP Rating IP66
Maximum Current 3 A ac, 270 mA dc
Maximum Operating Temperature +70°C
3 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 291.55
(exc. GST)
$ 320.71
(inc. GST)
units
Per unit
1 +
$291.55
Related Products
Telemecanique XY2CED emergency stop dual rope pull switches ...
Description:
Telemecanique XY2CED emergency stop dual rope pull switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress These dual rope pull switches feature double anchor points and can support up ...
These emergency stop trip wire switches are designed ...
Description:
These emergency stop trip wire switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress They can be tripped by a single human action when a normal emergency stop function ...
Telemecanique XY2CE EX ATEX emergency stop rope pull ...
Description:
Telemecanique XY2CE EX ATEX emergency stop rope pull switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress They can be tripped by a single human action when a normal ...
These emergency stop trip wire switches are designed ...
Description:
These emergency stop trip wire switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress They can be tripped by a single human action when a normal emergency stop function ...