9V ac 1 Output Through Hole PCB Transformer, 10VA

  • RS Stock No. 732-0421
  • Mfr. Part No. VC 10/1/9
  • Manufacturer Block
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

PCB Mount 230Vac Primary VC/VCM Series

Single and twin secondary windings for series or parallel connection
Vacuum resin moulded to UL94-V0 rating
Low inter-winding capacitance
Low radiated noise
100% electrical and flash tested
Extra fixing points for secure board mounting (25 VA and 36 VA)

Note

To conform to VDE 0550,UL506 all transformers with 2 x 24V outputs should not have their secondaries connected in series.

Standards

EN 61 558 IEC 61558

Approvals

ENEC, UL recognised

//media.rs-online.com/t_line/L347248-01.gif
//media.rs-online.com/t_line/L7320547-01.gif

Approvals

VDE; UL

Standards

EN 61 558; IEC 61558

Specifications
Attribute Value
Secondary Voltage Rating 9V ac
Power Rating 10VA
Primary Voltage Rating 230V ac
Number of Outputs 1
Length 51mm
Width 43mm
Depth 34.6mm
Dimensions 51 x 43 x 34.6mm
Weight 280g
Mounting Type Through Hole
Maximum Temperature +40°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
24 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 13.46
(exc. GST)
$ 14.81
(inc. GST)
units
Per unit
1 - 9
$13.46
10 - 24
$13.09
25 - 49
$12.59
50 - 99
$11.99
100 +
$11.70
Related Products
PCB mounting mains transformers with a single 230Vac. ...
Description:
PCB mounting mains transformers with a single 230Vac. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Thermal fuse in primary providing ...
RS Pro PCB low profile transformers are low ...
Description:
RS Pro PCB low profile transformers are low voltage transformers with a twin 115 V ac 50/60 Hz primary winding These PCB transformers are compact and low height, have independent secondary windings suitable for series/ parallel connection to give output ...
Dual 115Vac. 50 to 60Hz primary Twin secondary ...
Description:
Dual 115Vac. 50 to 60Hz primary Twin secondary windings for series or parallel connection AVB series are inherently short circuit proof compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins100% electrical and flash ...
230Vac. 50 to 60Hz primary Single or twin ...
Description:
230Vac. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have ...