15V ac 2 Output Through Hole PCB Transformer, 5VA

  • RS Stock No. 170-7417
  • Mfr. Part No. VC 5/2/15
  • Manufacturer Block
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

PCB Mount 230Vac Primary VC/VCM Series

Single and twin secondary windings for series or parallel connection
Vacuum resin moulded to UL94-V0 rating
Low inter-winding capacitance
Low radiated noise
100% electrical and flash tested
Extra fixing points for secure board mounting (25 VA and 36 VA)

Selection Guide
VA Rating Pin configuration (mm)      
  P1 S1 S2 A
3.2VA 20 10 5 25
5VA 25 15 5 25
10VA 25 15 5 27.5
16VA 30 20 5 30
Selection Guide
VA Rating Fixing centres (mm)   Pin configuration (mm)      
  C1 C2 P1 S1 S2 A
25VA 72.5 43.5 30 20 5 32.5
36VA 77.5 47.5 35 20 5 35
50VA 82 37.5 35 15 - 35
Isolation Primary to Secondary 5kVac Secondary to Secondary 250Vac
Protection Class 2
Insulation Class B (130°C)
Pin Length x Diameter 5mm x 0.8mm
Max. Ambient Temperature 3.2VA +60°C,5VA +50°C, 10 to 36VA +40°C

Note

To conform to VDE 0550,UL506 all transformers with 2 x 24V outputs should not have their secondaries connected in series.

Standards

EN 61 558 IEC 61558

Approvals

ENEC, UL recognised

Specifications
Attribute Value
Secondary Voltage Rating 15V ac
Power Rating 5VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 44mm
Width 33mm
Depth 37mm
Dimensions 44 x 33 x 37mm
Weight 190g
Mounting Type Through Hole
Efficiency 68%
Maximum Temperature +50°C
48 In stock for delivery within 5 working day(s)
Price (ex. GST) Each (In a Tray of 48)
$ 10.519
(exc. GST)
$ 11.571
(inc. GST)
units
Per unit
Per Tray*
48 +
$10.519
$504.912
*price indicative
Related Products
This range of covered (up to 320 VA) ...
Description:
This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double winding.Secondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or plug-in jumpers (from ...
Use as power, safety or displacement transformers in ...
Description:
Use as power, safety or displacement transformers in accordance with the applicable EN normHigh short-term performanceLow switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main sideElectrically isolated coilsScrew terminal connectors.
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connectionTwin secondary windings for series or parallel connectionLow profile compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedLow inter-winding ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...