Schneider Electric Phase Monitoring Relay With DPDT Contacts, 3 Phase, 200 → 240 V ac

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): ID
Product Details

Zelio Control Relays monitor and detect abnormal operating conditions about phases, current, voltage, frequency, speed, or temperature

Three-Phase Asymmetry Control Relay 200…240vac, 2 C/O

Specifications
Attribute Value
Monitoring Application Phase
Supply Voltage 200 → 240 V ac
Contact Configuration DPDT
Voltage Sensitivity Overvoltage
Electrical Phase 3
Voltage Sensing Range <100 V ac
Time Delay 30 s
Series Zelio Control
Operating Temperature Range -20 → +50 (60 Hz) °C, -20 → +60 (50 Hz) °C
Terminal Type Screw
Mounting Type DIN Rail
Dimensions 22.9 x 79.5 x 90 mm
Height 90mm
Maximum Voltage Sensed 240V ac
Maximum Operating Temperature +50 (60 Hz) °C, +60 (50 Hz) °C
Current Range 8 (AC) A, 10 (DC) mA
Length 22.9mm
Minimum Operating Temperature -20°C
Minimum Voltage Sensed 200 V ac
Width 79.5mm
On back order for despatch 03/08/2020, delivery within 5 working days from despatch date.
Price (ex. GST) Each
$ 462.23
(exc. GST)
$ 508.45
(inc. GST)
units
Per unit
1 +
$462.23
Related Products
Phase sequence relay, BA9041 Detects phase sequence errors ...
Description:
Phase sequence relay, BA9041 Detects phase sequence errors and phase failurewith 2 changeovers Overall width 45 mm The BA9041 can recognise the phase sequence L1 - L2 - L3 of a three-phase network and therefore avoid an incorrect rotational directionThe ...
DIN Style Single Phase Over Current Relay Multi ...
Description:
DIN Style Single Phase Over Current Relay Multi range Adjustable hysteresis Latching facility Adjustable fault delay Adjustable start -up delay Switchable relay inversionLED indication Write on ID tab Dimensions: H78 x W45 x D99mm Multi range Adjustable hysteresis Latching facility ...
CM-PBE Phase Loss Monitor Monitors 1-phase & 3-phase ...
Description:
CM-PBE Phase Loss Monitor Monitors 1-phase & 3-phase supply voltages for phase failure On fault, relay de-energizes & yellow LED turns off5% fixed hysteresis05 sec fixed OFF delay. Monitors 1-phase & 3-phase supply voltages for phase failure. On fault, relay ...
Load monitor LWN mecotron Mainly used for asynchronous ...
Description:
Load monitor LWN mecotron Mainly used for asynchronous motors (cage rotors) on a single-phase or 3-phase network with significantly changing loads The internal electrical isolation of the supply and measuring circuits means it can be used in networks that are ...