RS PRO 50VA Isolating Transformer, 230 V ac, 245 V ac, 400 V ac, 415 V ac Primary 1 x, 230V ac Secondary

  • RS Stock No. 504-307
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

Control Panel Primary 230/400Vac with +15Vac Tap

High quality safety and isolating transformers designed for use in control circuits and general applicationsLow loss noise laminationsDual standard primary winding 230 / 400Vac with +15V tap for input flexibilityDual secondaries are centre tapped. Earth terminal providedVarnish impregnated for overall protection against humidity and rustingFully shrouded cage clamp terminal with voltage markingsDetailed product specification on permanent labelHigh efficiency, low regulation design

Approvals

8888

Standards

BS EN 61558

Laminated

Specifications
Attribute Value
Primary Voltage Rating 230 V ac, 245 V ac, 400 V ac, 415 V ac
Secondary Voltage Rating 230V ac
Power Rating 50VA
Mounting Type DIN Rail
Number of Outputs 1
Length 84mm
Width 84mm
Depth 91mm
Dimensions 84 x 84 x 91mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Maximum Temperature +35°C
Weight 1.9kg
3 : Next working day (AU stock)
183 : 7 working days (Global stock)
Price (ex. GST) Each
$ 99.29
(exc. GST)
$ 109.22
(inc. GST)
units
Per unit
1 - 9
$99.29
10 - 24
$94.75
25 - 49
$91.61
50 +
$88.42
Related Products
ABT7PDU series transformers This range of covered (up ...
Description:
ABT7PDU series transformers This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double windingSecondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or ...
Control transformers, 1-phase, 4AM Series Use as power, ...
Description:
Control transformers, 1-phase, 4AM Series Use as power, safety or displacement transformers in accordance with the applicable EN norm High short-term performance Low switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main side Electrically ...
Control Panel Primary 690Vac (63/2500VA) Low inrush current ...
Description:
Control Panel Primary 690Vac (63/2500VA) Low inrush current control, safety isolating and isolating transformer Screw type terminals, fitted with screw mounting brackets Compact design with ±20V tappings on the primary winding For use up to +40°C ambient maximum Low inrush ...
Description:
Type UI 39 - 10 VA → 30 VA Secondary voltages are nominal load voltages on resistive loadsOnly the pins indicated on the wiring diagram "physically" exist. Standards IEC 742, VDE 0551, SEV 1003 Approvals UL 506. Secondary voltages are ...