Phoenix Contact 1 Channel Galvanic Barrier, Repeater power supply, Current Input, Current Output, ATEX
- RS Stock No.:
- 709-9644
- Mfr. Part No.:
- 2924016
- Brand:
- Phoenix Contact
- RS Stock No.:
- 709-9644
- Mfr. Part No.:
- 2924016
- Brand:
- Phoenix Contact
Technical data sheets
Legislation and Compliance
- COO (Country of Origin):
- DE
Product Details
Ex-i Repeater Power Supply and Input Isolation Amplifier, HART
Phoenix Contact brings you a brilliant Ex I repeater power supply and input signal conditioner. This signal conditioner has an integrity rating of SIL 2 (safety integrity level), official zone 2 installation support and bidirectional HART transmission. The 2865340 has been specifically designed for intrinsically safe and electrically isolated operation of measuring transducers and mA current sources installed in hazardous areas.
Features and benefits:
Ex-i repeater power supply and input isolation amplifier, HART
Sends fed or active 0/4-20 mA signals from the Ex area to a load
(active or passive) to the safe area
Electrical 3-way isolation, SIL 2 in accordance with IEC 61508
Sends fed or active 0/4-20 mA signals from the Ex area to a load
(active or passive) to the safe area
Electrical 3-way isolation, SIL 2 in accordance with IEC 61508
Intrinsic safety:
The 2865340 was designed to be used in intrinsically safe circuits. EX zone 0 and EX zone 20.
Accessories:
Approvals
CE-compliant
Group and Category
EN 61326, ATEX II (1) GD [Ex ia] IIC, Ex II 3 (1GD) G Ex nA [ia] IIC T4, [Ex ia] IIC; Ex nA[ia] IIC T4, SIL 2 according to EN 61508
Specifications
Attribute | Value |
---|---|
Number of Channels | 1 |
Module Type | Repeater power supply |
Barrier Type | Galvanic Barrier |
Output Signal Type | Current |
Maximum Voltage | 125 V dc, 253V ac |
Interface | HART |
Hazardous Area Certification | ATEX |
Input Signal Type | Current |
Safety Current Resistance | 600Ω |
Maximum Operating Temperature | +60°C |
Supply Voltage | 19.2 → 30V dc |
Maximum Current | 130mA |
Minimum Operating Temperature | -20°C |
Safety Current Maximum | 130mA |
Safety Voltage Maximum | 125 V dc, 253 V ac |
Series | MACX MCR-EX-SL-RPSSI |
Operating Temperature Range | -20 → +60°C |
Related links
- Zener & Galvanic Barriers
- Eaton 2 Channel Zener Barrier Current Input ATEX
- Phoenix Contact 2 Channel Galvanic Barrier Current Input, Current Output
- Eaton 1 Channel Zener Barrier Current Input ATEX
- PR Electronics 2 Channel Galvanic Barrier Current Current Output, ATEX
- Phoenix Contact 2 Channel Zener Barrier Current Input ATEX
- PR Electronics 1 Channel Galvanic Barrier Current Current, Voltage Output
- PR Electronics 2 Channel Galvanic Barrier Current Current ATEX