Fluke T6-1000, LCD Voltage tester, 1000V, Battery Powered, CAT III 1000V

  • RS Stock No. 146-2605
  • Mfr. Part No. T6-1000
  • Manufacturer Fluke
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

Fluke T6 Electrical Tester with FieldSense Technology.

Measure voltage … without test leads We know working in electrical boxes jammed with wires can be challenging when you’re trying to find a safe metallic contact point. Now with Fluke’s T6-600 or T6-1000 with integrated FieldSense technology you can quickly and easily take measurements by sliding the open fork over a conductor to see the voltage level without the need for test leads.

See how easy it is to make FieldSense measurements.

  • FieldSense tools Learn how to use the T6 Download the Quick Reference Guide Download the T6 "How-To" Demonstration Guide.

  • Read the FieldSense Proving Unit Demonstration Guide.

T6 Electrical Tester Helps Team at Cutting Edge Cancer Research Center, T6 Awards.

Why use the T6 Electrical Tester?

Electricians often work in boxes jammed with wires where finding a safe metallic contact point can be a challenge. With the T6-600 or T6-1000 you take measurements by sliding a single wire into the open fork.

How FieldSense Works:

FieldSense technology is truly a breakthrough in how voltage is measured. While other open fork testers detect a magnetic field to show ac current FieldSense technology detects an electrical field. This field interacts with a reference signal created by the T6 tester creating a voltage value on the tester’s display.

Who needs a T6 tester?

  • Commercial and light industrial electricians can use T6 Electrical Testers for most everyday measurements.

  • These devices easily fit in your pocket making them easy to access on the front-line for electricians of all industries.

  • Voltage measurement requires capacitive path to ground provided through user in most applications.

  • Ground connection via test lead may be required in some situations.

  • Measure voltage up to 1000 V ac through the open fork without test lead contact to live voltage without opening covers or removing wire nuts.

  • On wires up to AWG 4/0 (120 mm2) carrying as much as 200 A.

  • It will change your job.


  • Safer.

  • Faster.

  • Easier.

  • Requires capacitive path to ground provided through user in most applications.

  • Ground connection via test lead may be required in some situations.

Product Highlights.

  • FieldSense technology for ac voltage current and frequency measurement without making electrical contact to live voltage.

  • Simultaneous voltage and current display – shows all power supply measurements at a glance for efficient trouble shooting 1 to 1000 V ac or dc (T6-1000) 0 to 200 A ac True-rms voltage and current Resistance 1 Ω to 100 kΩ.

  • Frequency measurement 45 Hz to 66 Hz Works with wires up to AWG 4/0 (120 mm2) with a 17.8 mm jaw opening HOLD button temporarily freezes the reading for easy viewing.

  • Easy to read display with backlight accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation.

  • Standard two-year warranty; extendable to 4 years through product registration within 45 days of purchase.

Tips:

  • FieldSense Technology - Do not hold or touch wire you are testing during a measurement.

  • Use the black probe to make the ground connection if: wearing gloves or insulated footwear standing on an insulated ladder additional ground contact is required for the application.
  • FieldSense measurement looks like this when properly grounded: Display colour turns green.

  • Display shows a valid measurement >16 V rather than dashes or 0.0 shows for measurement ≥30 V.

  • Voltage measurement requires capacitive path to ground provided through user in most applications. Ground connection via test lead may be required in some situations.

  • Register product online within 45 days of purchase to extend warranty to four years. See http://a.fluke.com/registration for details.

  • Two-year additional warranty offer may be discontinued without notice.

  • Be safer: Measure voltage to 1000 V ac through the open fork without test leads.

  • Be faster: No need to open covers or remove wire nuts.

  • Be more efficient: Simultaneously measure voltage and current.

  • Be everywhere: 17.8 mm open fork is widest in the industry. measure up to 200 A on 4/0 wires (120 mm2).

  • Go beyond simple detection.

  • Actually measure ac voltage and current values without test leads.

Frequently asked questions and answers:

Why use the T6 Electrical Tester?

Electricians often work in boxes jammed with wires, where finding a safe metallic contact point can be a challenge. With the T6-600 or T6-1000 you take measure

Does this come with a calibration certificate?

Calibration is an additional service that we provide to customers. Calibrated products have an appropriate information shown within the product specification section at the bottom of the page. For more information please contact our Customer Service Centre.

Note

Do not hold or touch wire you are testing during a measurement. Use the black probe to make the ground connection if:
• wearing gloves or insulated footwear
• standing on an insulated ladder
• additional ground contact is required for the application

Specifications
Attribute Value
Maximum Voltage 1000V
Safety Category CAT III 1000 V, CAT IV 600V
Display Type LCD
Battery Type AA IEC LR6
Power Source Battery
Dimensions 61.1 x 43.8 x 259.3mm
Weight 350g
Height 259.3mm
Length 61.1mm
Maximum Operating Temperature +50°C
Safety Category Level CAT III, CAT IV
Minimum Operating Temperature -10°C
Safety Category Voltage 600 V, 1000 V
Width 43.8mm
Model Number p T6-1000
23 In stock for delivery within 1 working day(s)
Price (ex. GST) Each
Was $399.00
$ 379.05
(exc. GST)
$ 416.95
(inc. GST)
units
Per unit
1 +
$379.05
Related Products
MS-918-PG Voltage Multi-Tester MS-918-PG is a voltage absence ...
Description:
MS-918-PG Voltage Multi-Tester MS-918-PG is a voltage absence tester in accordance with EN 61243-3 (2010) In response to the requirements of the new standard NF C 18-510 and with the European standard EN 50110-1.MS-918-PG ensures both VCU function and extra ...
For safe and reliable live indication Suitable for ...
Description:
For safe and reliable live indication Suitable for non-contact AC voltage tests, earthing/ground connection checks, proper connection checks, broken wire detection High sensitivity tester offering an extensive non-contact voltage detection range of 70-1000V ACBright red LED illumination on detection of ...
Digicheck 32 Digi check 3.2 with AC/DC range ...
Description:
Digicheck 32 Digi check 3.2 with AC/DC range and continuity test on a 2000 count LCD display, with back light. Automatic range selection Illuminated measuring probes Audible buzzer on continuity test Display hold function Polarity (+/-) check Single pole phase ...
Drummond Test Lamps MTL10 Bright LED indication of ...
Description:
Drummond Test Lamps MTL10 Bright LED indication of voltage between 50V and 500V AC/DC Four distinct bands of illumination above 50, 100, 200 and 400V AC/DC with a 360o viewing angle even in bright sunlight Identifies potentially lethal voltages at ...