ETA 2A 1 Pole Thermal Magnetic Circuit Breaker, 48 V dc, 250 V ac 106-P30

  • RS Stock No. 335-996
  • Mfr. Part No. 106-P30-000040-2A
  • Manufacturer ETA
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

106-P30 Series

PCB, single hole mounting
Sub-miniature, double insulated
Trip free mechanism
Slow response time (typically 30 seconds at twice nominal current rating) ideal for inductive/reactive loads
Typical life 5000 operations (0.5 to 3A)/1000 operations (4 and 5A) at twice nominal current rating
Mainly for motors, transformers and power supplies
IEC Classification R/TO

Approvals

UL; CSA; VDE; SEV and NEMKO

Approvals

UL/CSA; VDE; SEV; NEMKO

Specifications
Attribute Value
Current Rating 2A
Number of Poles 1
Width 19mm
Series 106-P30
21 : Next working day (AU stock)
605 : 5 working days (Global stock)
Price (ex. GST) Each
$ 23.12
(exc. GST)
$ 25.43
(inc. GST)
units
Per unit
1 - 14
$23.12
15 - 49
$22.54
50 - 99
$21.95
100 - 249
$21.34
250 +
$20.80
Related Products
Single-pole thermal/magnetic circuit breakers which may be housed ...
Description:
Single-pole thermal/magnetic circuit breakers which may be housed in any of the modular DIN 43 880 enclosures (refer to the Enclosures Sections). The speed of operation together with the availability of low current ratings offer the possibility of finely tuned ...
Rocker switch and thermal circuit breaker (CBE) combinedTrip-free ...
Description:
Rocker switch and thermal circuit breaker (CBE) combinedTrip-free mechanismSnap-in panel mountingPanel thickness 1 to 2.5 mmBlade terminals DIN 46244-C-Ms-SOverload protection on all poles (multi-pole)Typical life 30000 operations at nominal current ratingMain applications for motors, white goods industries, ...
Overload and short circuit protecting, DIN rail mounting, ...
Description:
Overload and short circuit protecting, DIN rail mounting, time delay type thermal-magnetic single-pole CBE, suitable for process control, telecom and other professional/precision applications, etc. Toggle operated trip-free mechanismAuxiliary contact (NC) for remote signalling of contact breaker statusNarrow ...
IEC Classification S/TO (with module, S/TM),This range of ...
Description:
IEC Classification S/TO (with module, S/TM),This range of low cost switch and circuit breaker are an economic way of providing basic protection for equipment.,Typical tripping times at 2xIN, 20-30 seconds faster time can be achieved with the addition of the ...