Murrelektronik MU..W 6.2 Signal Conditioner

MurrElektronik MUW 6.2 series analog converters convert standard signal formats galvanically separated into a 4 mA to 20 mA signal. An integrated current limiter ensures the output is short-circuit and overload protected.

Features and Benefits

Status LED Input and output galvanically separated
Screw terminals
35mm DIN Rail mounting

Murrelektronik Signal Conditioners

Specifications
Attribute Value
Input Range 0 → 10 V dc
Output Range 4 → 20 mA
Supply Voltage 0 → 10 V dc
Mounting Type DIN Rail
Minimum Operating Temperature 0°C
Maximum Operating Temperature +60°C
Standards Met EN 60715
Operating Temperature Range 0 → +60 °C
Number of Channels 1
Termination Screw
2 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 353.52
(exc. GST)
$ 388.87
(inc. GST)
units
Per unit
1 +
$353.52
Related Products
Signal Conditioning Units RS Pro single or dual ...
Description:
Signal Conditioning Units RS Pro single or dual trip amplifiers with the facility to arrange each trip so that the alarm condition can be above (high trip) or below (low trip) the set point The relay can be either energise/de-energise ...
SIRIUS 3RS70 Signal Converter Siemens Sirius 3RS70 signal ...
Description:
SIRIUS 3RS70 Signal Converter Siemens Sirius 3RS70 signal converters perform the coupling function for analogue signals on both the input side and the output side They are indispensable when processing analogue values with electronic controls. Under harsh industrial conditions in ...
Murrelektronik MTW 124 Temperature Converter Murr Elektronik MTW ...
Description:
Murrelektronik MTW 124 Temperature Converter Murr Elektronik MTW 12.4 series temperature monitoring relays are designed specially for monitoring abnormal temperatures to prevent excessive temperature increase and to protect equipment. The temperature converter works in conjunction with a PT100 temperature sensor ...
Analogue Signal to Frequency Converter Switch selectable input ...
Description:
Analogue Signal to Frequency Converter Switch selectable input signal ranges Output selectable by terminals Offset and gain adjustable ±5%LED indication below 5% input Galvanic isolation input to output to supplyNPN – PNP output device; 30Vdc max Switch selectable input signal ...