Block, 500VA TIM Isolation Transformer, 230V ac, 2.17A

  • RS Stock No. 436-9808
  • Mfr. Part No. TIM500
  • Manufacturer Block
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Single Phase 230Vac Input, 12Vac or 24Vac and 115Vac or 230Vac Output, Short Circuit Proof, Safety Isolating Transformers

Brought to you by Block, this range of Safety Isolating Transformers are short-circuit proof and feature thermal overload protection. The single phase transformers are provided with mounting holes for easy installation, and have two independent secondary windings, which may be connected in series or parallel. These highly efficient safety isolating transformers have integrated primary fuse protection.

Block Safety Isolating Transformers benefit from the following features:

• Encapsulated in plastic housing upto 300VA
• Housed in metal enclosures from 500VA
• Screw terminals on input and output
• Strain relief for connecting leads
• Dual output for series or parallel connection
• High efficiency 88% typical
• 100% electrical and 5kV flash tested
• Max ambient temp: +40°C
• Insulation category: Class B (Typical)
• Construction: Class 2
• Protection index: IP20

Standards

EN61558, VDE 0570, UL506.

Approvals

EN61-558, VDE 0570, UL506.

Approvals

EN61-558; VDE 0570; UL506; CUL506

Standards

VDE 0570; EN 61558-1; EN 61558-2-6; UL 506; CSA 22.2

Specifications
Attribute Value
Primary Voltage Rating 230V ac
Secondary Voltage Rating 115V ac
Power Rating 500VA
Output Current 2.17A
Series TIM
Weight 9.1kg
Width 150mm
Depth 176mm
Mounting Type Chassis Mount
Maximum Temperature +40°C
8 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 192.65
(exc. GST)
$ 211.91
(inc. GST)
units
Per unit
1 - 9
$192.65
10 - 24
$188.16
25 - 49
$185.86
50 - 99
$182.14
100 +
$178.50
Related Products
On coil energisation the mechanical latch is engaged ...
Description:
On coil energisation the mechanical latch is engaged & holds the armature closedThis feature enables the contactors state to be maintained when re-starting after an interrupted cycle & allows power consumption reduction by enabling de-energisation of the contactor coil. Remotely ...
3TF power contactors from Siemens has been designed ...
Description:
3TF power contactors from Siemens has been designed for switching and controlling squirrel cage and slip-ring motors as well as other AC loads, such as solenoids, capacitors, lighting loads, heating loads and transformer loads SICOP contactors and bi-relays and have ...
230Vac input 24Vdc (nom) output safety isolating transformer ...
Description:
230Vac input 24Vdc (nom) output safety isolating transformer to VDE0551, EN607424kV input/output flash tested Finger safe easy accessible screw terminals Double screw terminals on the output Input and output fuse protectionLED output voltage indicator Parallelable (with same type)Electrolytic capacitor in ...
RS Pro Distribution Unit for splitting a single ...
Description:
RS Pro Distribution Unit for splitting a single 110 V supply to 4 socket outlet Made with a robust GRP enclosure complete with 4x16A 110v Sockets and 5M of 2.5 mm 2 3 core Arctic Grade Cable. Class 1.