Carroll & Meynell, 750VA CM1500WM0 Safety Transformer, 230V ac, 8.18A

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

Single Phase, 230Vac Input, 110Vac Output Transformers

High quality wall mounting safety isolating transformers designed to ensure safe electrical distribution for power tools etc in industrial, garage and other fixed installations.

Double wound
110V secondaries centre tapped to earth to minimise shock risk
Sheet steel IP22 type wall mounting enclosure
Re settable thermal cut out trip in primary circuit to prevent overload
Thermal safety overload fuse embedded into primary winding
20mm conduit entry on both sides of case

Note

Tool rating is defined in BSEN 61558-2-23 as 5 minutes on and 15 minutes off. Maximum output must not exceed 16A per socket outlet.

Approvals

8888

Standards

BSEN 61558-2-23

Specifications
Attribute Value
Primary Voltage Rating 230V ac
Secondary Voltage Rating ±110V ac
Power Rating 750VA
Output Current 8.18A
Series CM1500WM0
Plug Type Hard Wire L-N-E
Weight 10.5kg
Length 200mm
Width 176mm
Depth 226mm
Dimensions 200 x 176 x 226mm
Mounting Type Wall Mount
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
20 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 400.36
(exc. GST)
$ 440.40
(inc. GST)
units
Per unit
1 - 9
$400.36
10 - 24
$390.33
25 - 49
$369.79
50 - 99
$358.93
100 +
$349.94
Related Products
Autowound transformers for step-up or step-down of mains ...
Description:
Autowound transformers for step-up or step-down of mains voltages at 50/60Hz. , Compact construction Full varnish impregnation Fully shrouded Four-hole fixing for permanent installation Terminal blocks with protective covers (except 50VA which has leads) 100% electrical and flash tested (2kV ...
Autowound transformers for step-up or step-down of mains ...
Description:
Autowound transformers for step-up or step-down of mains voltages at 50/60Hz. , Compact construction Full varnish impregnation Fully shrouded Four-hole fixing for permanent installation Terminal blocks with protective covers (except 50VA which has leads) 100% electrical and flash tested (2kV ...
The two independent secondary windings may be connected ...
Description:
The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Optional terminal shrouds for 75VA and 100VA.
Applications include fridges, freezers, air conditioning and coolersDesigned ...
Description:
Applications include fridges, freezers, air conditioning and coolersDesigned to accurately stabilise large variations of mains voltageIncludes lightning surge/spike protectionDisconnects output when mains voltage is too high or too low3 minute wait period to allow compressor gases to neutralise before ...