Flexi Soft Input Module, 8 Inputs, 24 V dc

  • RS Stock No. 701-9199
  • Mfr. Part No. FX3-XTDI80002
  • Manufacturer Sick
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

SICK I/O Digital Module

The SICK I/O digital module has 8 numbers of input and output terminals. This module has an input supply voltage of 13VDC to 30VDC and an output voltage ranging from 15VDC to 30VDC via FLEXBUS+. This module enables safety functions like E-stop function, machine control (e.g. PSDI), differentiation between man and material (muting), control modes and operating mode selection.

Features and Benefits

8 control outputs (with 2 test pulse generators)
Safety functions
Connects to main system via cable gland
Operating temperature ranges between –25°C and 55°C

Certifications

EN ISO 13849
SIL3 (IEC 61508)
SILCL3 (IEC 62061)
EN ISO 13848
IP20 rated (Enclosure)
CE certified
cULus approved
CCC certified

Specifications
Attribute Value
Series Flexi Soft
Type Input Module
For Use With Flexi Soft
Supply Voltage 24 V dc
Number of Inputs 8
Power Rating 5 W
Mounting Style DIN Rail
Dimensions 96.5 x 22.5 x 120.8 mm
Terminal Type Clamp
4 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 380.62
(exc. GST)
$ 418.68
(inc. GST)
units
Per unit
1 +
$380.62
Related Products
Input expander / PFB For SD-Interface devices Passive ...
Description:
Input expander / PFB For SD-Interface devices Passive field box for series-wiring For devices with M12 Connector, 8-pole For up to 4 safety switchgears Fuse protected device ports Heavy duty version for field installation Protection class IP67.
The Dold LG5929 series emergency stop module has ...
Description:
The Dold LG5929 series emergency stop module has a single-channel 5NO/1NC normal state configuration This extension unit has a supply voltage of 24VDC/AC. 1 semiconductor output Line fault detection on on-button Manual restart or automatic restart, switch S2With or without ...
UE410-MM3 Muting Main Unit and UE410-XM3 Muting Extension ...
Description:
UE410-MM3 Muting Main Unit and UE410-XM3 Muting Extension Functions include muting and override, concurrence monitoring, monitoring total muting time, sensor gap monitoring, end of muting by ESPE Applications: Opto-electronic protective devices and non-contact safety switches 2 or 4 muting sensors1 ...
Flexi Soft Extension Unit, FX3-XTIO84002 8 safety inputs, ...
Description:
Flexi Soft Extension Unit, FX3-XTIO84002 8 safety inputs, 4 safety outputs and 2 control outputs Type of safety capable outputs: PNP semiconductors, short-circuit protected, cross-circuit monitored Operating mode switching Fast shut-off: 9 ms Maximum output current: 2AMaximum power consumption: 3WResponse ...