2P 6 kA, 15 kA 16 A RCBO, DIN Rail Mount, Trip Sensitivity 30mA Sentron 5SU1

  • RS Stock No. 151-1208
  • Mfr. Part No. 5SU1356-6KK16
  • Manufacturer Siemens
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): RO
Product Details

Siemens 5SU1 RCBOs

The 5SU1 series from Siemens are a range of RCBOs in a compact design. Rated with a residual current of maximum 30 mA is suitable for personnel, material and fire protection, as well as for protection against direct contact.

RCBOs comprise one part for fault-current detection and one part for overcurrent detection. They are equipped with a delayed overload/time-dependent thermal release (thermal bimetal) for low overcurrents and with an instantaneous electromagnetic release for higher overload and short-circuit currents.

Conductor connection easily checked in front of the busbar
Large accessible wiring space enables easy insertion of conductor in the terminals
The surge current withstand capability of > 1 kA ensures safe and reliable operation
All additional components for miniature circuit breakers can be retrofitted on the right-hand side

Specifications
Attribute Value
Range Sentron
Series 5SU1
Current Rating 16 A
Trip Sensitivity 30mA
Number of Poles 1+N
Mounting Style DIN Rail
Standards Met CCC, CE, DIN EN 61346-2, DIN EN 81346-2, EN 60898, IEC 60947-2, VDE
Overall Width 90mm
Reset Actuator Type Toggle Switch
Circuit Breaker Type RCBO
Terminal Contact Type Screw
Overall Dimensions 35.4 x 90 x 76.2mm
Overall Length 35.4mm
Tripping Characteristics Type B
Rated AC Voltage 230 V
Breaking Capacity 6 kA, 15 kA
Break Time Instantaneous
Overall Depth 76.2mm
7 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 162.40
(exc. GST)
$ 178.64
(inc. GST)
units
Per unit
1 +
$162.40
Related Products
Auxiliary contacts for DF fuse-holders These auxiliary contacts ...
Description:
Auxiliary contacts for DF fuse-holders These auxiliary contacts indicate pre-cutoff, blown fuses (if the fuse-holder features a fuse striker) and fuse presence These auxiliary contacts indicate pre-cutoff, blown fuses (if the fuse-holder features a fuse striker) and fuse presence.
Acti9 Auxiliaries The electrical auxiliaries are combined with ...
Description:
Acti9 Auxiliaries The electrical auxiliaries are combined with iC60 circuit breakers, iID residual current circuit breakers, remote tripping switch disconnector iSW-NA , RCA remote controls and ARA automatic reclosers; they enable tripping or remote indication of their position (open/closed/tripped) upon ...
Sprint Electric Fully Isolated DC Drive Adaptable range ...
Description:
Sprint Electric Fully Isolated DC Drive Adaptable range of slimline range of controllers suitable for use with both permanent magnet and shunt wound DC motors the compact design provides the user with a space saving solution to motor control Fully ...
UNO Primary Switched DC-DC converter Primary-switched UNO DC-DC ...
Description:
UNO Primary Switched DC-DC converter Primary-switched UNO DC-DC converter with wide range input and basic functionality, suitable for DIN Rail mountingWith these DC-DC converters, the control cabinet is supplied directly from the photovoltaic system saving installation costs and increasing the ...