XY2-CH Cable Switch, Straight, 15m, 2NC

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): MA
Product Details

Telemecanique XY2CH Emergency Stop Rope Pull Switches

The XY2-CH emergncy stop rope pull switch (also known as a grab wire switch) is ideal for applications such as conveyor systems, packaging, textiles, transfer machines, presses, woodworking equipment, paint lines and test laboratories.

For machine tools, conveyers & handling applications
Recommended distance between cable supports: 5m
Built-in turnbuckle accessory
Pushbutton reset
Water and dust tight enclosure
Surface mount

Note

Manufacturer part numbers with the suffix H29 are the ISO M20 threaded cable entry version.

Approvals

UL Listed file number: E164353 CCN NKCR. CSA certified file number: LR44087 class 3211 03. CE marked.

Specifications
Attribute Value
Range Preventa
Series XY2-CH
Reset Button Yes
Pole Configuration DP
Normal State Configuration 2NC
Mounting Orientation Straight
Maximum Rope Span 15m
Maximum Current 3 A ac, 270 mA dc
Maximum AC Voltage 240V
Maximum DC Voltage 250V
Number of Cable Entries 3
Conduit Entry M20 x 1.5
Size of Cable Entries M20 x 1.5
Length 68mm
Dimensions 68 x 201 x 95 mm
Maximum Operating Temperature +70°C
Depth 95mm
Width 201mm
IP Rating IP65
E-Stop Button No
Minimum Operating Temperature -25°C
8 : Next working day (AU stock)
13 : 5 working days (Global stock)
Price (ex. GST) Each
$ 309.12
(exc. GST)
$ 340.03
(inc. GST)
units
Per unit
1 - 2
$309.12
3 - 4
$270.49
5 +
$243.44
Related Products
Even under extreme conditions, such as major temperature ...
Description:
Even under extreme conditions, such as major temperature fluctuations, the SRM rope pull switch continues to work reliably. Rope pull switch manufactured in accordance with DIN EN 60947-5-5 and DIN EN ISO 13850Protection class IP67Stable and durable metal housing (aluminium ...
These emergency stop trip wire switches are designed ...
Description:
These emergency stop trip wire switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. They can be tripped by a single human action when a normal emergency stop function ...
Maximum system length: 75 mSwitch function: 2 NC ...
Description:
Maximum system length: 75 mSwitch function: 2 NC + 2 NO (standard)Built-in reset buttonCable pull eyelet, low costVisualisation of correct cable tensionMeets EN418 and IEC947-5-5Protection class IP67.
The 3SE7 series of grab wire switches (trip ...
Description:
The 3SE7 series of grab wire switches (trip wire switches, cable operated switches) are used for monitoring or for EMERGENCY STOP devices on particularly dangerous system sections.As the effective range of a grab wire switch is only limited by the ...