RS PRO RES5F Series 8A 250 V ac/dc 50/60Hz Chassis Mount RFI Filter, with Fast-On Terminals, Single Phase

  • RS Stock No. 386-4065
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): KR
Product Details

RES5F Series

Available in 5 current ratings
Meets UL 1283 and overvoltage II category of IEC 664
250 Faston terminals

Approvals

UL recognised component, CSA certified, TUV

Approvals

UL; CSA; TUV

Specifications
Attribute Value
Maximum Current Rating 8A
Maximum Voltage Rating 250 V ac/dc
Mounting Type Chassis Mount
Termination Style Fast-On
Number of Phases 1
Series RES5F
Number of Stages Single Stage
Operating Frequency 50/60Hz
Length 83.7mm
Depth 51.8mm
Height 32mm
Capacitance 3.3 nF, 100 nF
Dimensions 83.7 x 51.8 x 32
Inductance 3 mH
Minimum Operating Temperature -25°C
Leakage Current 0.5 mA
Maximum Operating Temperature +85°C
Resistance 1MΩ
65 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 37.03
(exc. GST)
$ 40.73
(inc. GST)
units
Per unit
1 - 4
$37.03
5 - 9
$35.19
10 - 24
$31.49
25 - 49
$29.64
50 +
$28.15
Related Products
Schaffner FN332Z series RFI filters are designed for ...
Description:
Schaffner FN332Z series RFI filters are designed for easy and fast access chassis mounting These filters have high saturation resistance and high inductivity.are also available with integrated surge Pulse protection to safeguard sensitive electrical equipment. Maximum continuous operating voltage 250 ...
EPCOS B84142-Bx-R Series Power line filters for convertors ...
Description:
EPCOS B84142-Bx-R Series Power line filters for convertors and power electronics These 2 line filters feature a high insertion loss due to its two stage construction, easy to install and has optimised leakage current. Rated voltage VR: 250 V AC/DC.Rated ...
Meets BS 6651:1992 Appendix C for Lightning protection ...
Description:
Meets BS 6651:1992 Appendix C for Lightning protection Fully tested to IEC1000-4-5 and IEC1000-4-6 these hybrid protectors provide a low let-through voltage whilst exhibiting high RFI attenuation (maximum 73dB at 5MHz)Designed to repeatedly handle surges of up to 6000V and ...
IEC Inlet plugs with integral mains filter Designed ...
Description:
IEC Inlet plugs with integral mains filter Designed to filter mains borne interference where capacitors alone may prove inadequate.Connection by 250 ( 1/4 in) receptacles. (For insulating boots see typically RS stock no. 526-0724).,Voltage 250Vac max. Operating frequency 50/60Hz.