Crouzet 2 → 8bar 2 → 8s Pneumatic Timer, -5 → +50°C

  • RS Stock No. 305-5996
  • Mfr. Part No. 81503720
  • Manufacturer Crouzet
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): FR
Product Details
//media.rs-online.com/t_line/L724891-01.gif
//media.rs-online.com/t_line/L724891-02.gif
//media.rs-online.com/t_line/LD724891-01.gif
//media.rs-online.com/t_line/LD724891-02.gif

Crouzet Pneumatic Timer

The Crouzet 81 series pneumatic adjustable positive time delay module requires operating pressure ranging between 2bar and 8bar. This timer has a counting range from 0.1 seconds to 30 seconds. On the application of a pilot signal, the reservoir starts to fill via the flow restrictor. After the set time delay the relay is operated and an output is given. This timer will not reset until the pilot signal is removed.

Features and Benefits

Orifice diameter is 2.7mm
Flow rate at 6bar is 170NL/minute
Mechanical operating life is >10^7
Operating temperature ranging between -5°C and 50°C

Certifications

ANSI/ESD S20.20:2014
BS EN 61340-5-1:2007

Specifications
Attribute Value
Manufacturer Series 81
Minimum Operating Pressure 2bar
Maximum Operating Pressure 8 bar
Minimum Operating Temperature -5°C
Maximum Operating Temperature +50°C
Minimum Time 0.1s
Maximum Time 30s
5 In stock for delivery within 1 working day(s)
Price (ex. GST) Each
$ 242.18
(exc. GST)
$ 266.40
(inc. GST)
units
Per unit
1 +
$242.18
Related Products
Pneumatic Time Delay Blue button, on delay Black ...
Description:
Pneumatic Time Delay Blue button, on delay Black button, off delay Suitable for use with A series contactors, A9 to A75,BC9 to BC30,N & KC contactor Relays Current rating 4A @ 230Vac Blue button, on delay Black button, off delay ...
Schneider Electric | Te Sys D LAD Series ...
Description:
Schneider Electric | Te Sys D LAD Series | Contactor Timer Professionally assembled contactor Timers by Schneider Electric provide you with the option of delaying timed functions on your control circuit linked via the main contactor This can be beneficial ...
Star-Delta Timer Pneumatics 1N/O + 1N/C timed auxiliary ...
Description:
Star-Delta Timer Pneumatics 1N/O + 1N/C timed auxiliary contacts Delay on40ms fixed delay between operation of N/O & N/C contacts Front, vertical mounting Professionally assembled Contactor Timers by Schneider Electric provide you with the option of controlling timed functions on ...
Time Delay Valve Combination of adjustable orifice and ...
Description:
Time Delay Valve Combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period Bracket and Panel mounting. Combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a ...