SMC 0.1 → 1Mpa 0.5 → 60s Time Delay Valve, -5 → +60°C

  • RS Stock No. 384-333
  • Mfr. Part No. VR2110-01
  • Manufacturer SMC
Technical data sheets
Legislation and Compliance
Non Compliant
COO (Country of Origin): JP
Product Details
//media.rs-online.com/t_line/L0384333-01.gif

SMC Pneumatic Timer

The SMC VR series time delay valve requires operating pressure ranging between 0.25MPa and 0.8MPa. This timer has a timing delay range from 0.5 seconds to 60 seconds. This timer is a combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time.

Features and Benefits

Supply pressure ranging between 0MPa and 1.0MPa
Repeatability is ±10% F.S
Effective area is 2.5mm^2
Port size is 1/8
Operating temperature ranging between -5°C and 60°C

Certifications

ANSI/ESD S20.20:2014
BS EN 61340-5-1:2007

Specifications
Attribute Value
Manufacturer Series VR
Minimum Operating Pressure 0.1MPa
Maximum Operating Pressure 1 MPa
Minimum Operating Temperature -5°C
Maximum Operating Temperature +60°C
Minimum Time 0.5s
Maximum Time 60s
2 : Next working day (AU stock)
25 : 5 working days (Global stock)
Price (ex. GST) Each
$ 292.89
(exc. GST)
$ 322.18
(inc. GST)
units
Per unit
1 +
$292.89
Related Products
The Omron H5CX-L series, economy type ultra-compact digital ...
Description:
The Omron H5CX-L series, economy type ultra-compact digital timer is a multifunction, single-channel device It has an 8-pin socket connection with time-limit SPDT + instantaneous SPDT contacts. It has operating voltage ranging between 100VAC and 240VAC. with 5A maximum current. ...
Timer Module A pneumatic timer consists of a ...
Description:
Timer Module A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves ...
The Crouzet 81 series pneumatic adjustable positive time ...
Description:
The Crouzet 81 series pneumatic adjustable positive time delay module requires operating pressure ranging between 2bar and 8bar This timer has a counting range from 0.1 seconds to 15 seconds. On the application of a pilot signal, the reservoir starts ...
The Crouzet 81 series single impulse generator has ...
Description: