Jumo 2 wire PT100 Sensor, -50°C min +400°C max, 250mm Probe Length x 9mm Probe Diameter

  • RS Stock No. 337-6805
  • Mfr. Part No. 902020/10-402-1003-1-9-250-104/000
  • Manufacturer Jumo
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): DE
Product Details

Screw-in resistance thermometer with terminal head, form B

For temperatures from -50 °C → +400 °C
With replaceable measuring insert
For temperature measurements in liquid and gaseous media
Good seal integrity both in instances of low pressure and overpressure
The connection head is suitable for ambient temperatures up to 100 °C
Protection tube protects the measuring insert from chemical influences and mechanical damage
Application areas include air-conditioning and refrigeration systems, heating system, oven and apparatus construction and the chemical industry

PT100  
Measuring rod Ø: 9 mm
Level gauge length (EL):
Thread:
160 / 250 / 400 mm
G 1//2
//media.rs-online.com/t_line/LD337679-01.gif
Specifications
Attribute Value
Sensor Type PT100
Probe Length 250mm
Probe Diameter 9mm
Minimum Temperature Sensed -50°C
Maximum Temperature Sensed +400°C
Termination Type Connection Head
Probe Material Stainless Steel
Process Connection BSP 1/2
Cable Entry Size M20
Number Of Wires 2
Accuracy Class B
Response Time 50 s
3 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 185.31
(exc. GST)
$ 203.84
(inc. GST)
units
Per unit
1 - 4
$185.31
5 - 9
$181.64
10 +
$179.76
Related Products
Heat meter resistance thermometers are preferably used in ...
Description:
Heat meter resistance thermometers are preferably used in closed-loop pipe systems. Installation in protective sleeves with fit tolerance or direct installation in ball valves eliminates the need to empty the system when exchanging the heat meter after expiration of the ...
Working temperature from -50 °C → +600 °CFlexible, ...
Description:
Working temperature from -50 °C → +600 °CFlexible, thin-walled sheathed wire made of stainless steel; the low-ohm copper internal conducting wires are embedded in compressed, fire-resistant magnesium oxide for vibration resistanceTwo or three-conductor circuitRapid response timesConnection lead made of silicon, ...
Sensors with one or two Pt 100, Class ...
Description:
Sensors with one or two Pt 100, Class A as per IEC751.3-wire or 2 x 3 wire fitting.316L stainless steel protected with hard-packed MgO insulation.Type A DAN connection head with BLS terminal block and PG16 cable gland output.
Resistance thermometer without fastening elementTemperature measurement and monitoring ...
Description:
Resistance thermometer without fastening elementTemperature measurement and monitoring on diverse application sitesTemperature range: -50 °C → +200 °C or +400 °CDesign with cable connection sleeveTwo or three-conductor circuitAccuracy class B2.5 m connection leadProtective tube Ø 3 x 50 mm with ...