12V ac 2 Output Through Hole PCB Transformer, 10VA

  • RS Stock No. 347-2616
  • Mfr. Part No. VC 10/2/12
  • Manufacturer Block
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

PCB Mount 230Vac Primary VC/VCM Series

Single and twin secondary windings for series or parallel connection
Vacuum resin moulded to UL94-V0 rating
Low inter-winding capacitance
Low radiated noise
100% electrical and flash tested
Extra fixing points for secure board mounting (25 VA and 36 VA)

Note

To conform to VDE 0550,UL506 all transformers with 2 x 24V outputs should not have their secondaries connected in series.

Standards

EN 61 558 IEC 61558

Approvals

ENEC, UL recognised

//media.rs-online.com/t_line/L347247-01.gif
//media.rs-online.com/t_line/L347248-01.gif
Specifications
Attribute Value
Secondary Voltage Rating 12V ac
Power Rating 10VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 51mm
Width 34.6mm
Depth 43mm
Dimensions 51 x 34.6 x 43mm
Weight 280g
Mounting Type Through Hole
Maximum Temperature +40°C
6 : Next working day (AU stock)
78 : 5 working days (Global stock)
Price (ex. GST) Each
$ 23.77
(exc. GST)
$ 26.15
(inc. GST)
units
Per unit
1 - 9
$23.77
10 - 24
$22.60
25 - 49
$21.22
50 - 99
$19.80
100 +
$19.30
Packaging Options:
Related Products
PCB mounting mains transformers with a single 230Va.c. ...
Description:
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Fully shrouded bobbinsExtra pins for ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connectionTwin secondary windings for series or parallel connectionLow profile compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedLow inter-winding ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...