9V ac 2 Output Through Hole PCB Transformer, 0.35VA

  • RS Stock No. 310-1190
  • Mfr. Part No. VB 0.35/2/9
  • Manufacturer Block
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Transformers PCB Mount, Short Circuit Proof, VB & PT Series

230Va.c. 50 to 60Hz primary
Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval)
VB series (0.35 - 3.2VA) are inherently short circuit proof
PT series (4.5 - 22VA) are protected by internal PTC device
Compact design
Vacuum epoxy resin moulded to UL94-V0 rating
Double section glass fibre reinforced polyamide bobbins
100% electrical and flash tested
High efficiency and low temperature rise
Low inter-winding capacitance
Low radiated noise
Extra fixing holes for secure boarding mounting on 4.5VA and above

Standards

EN 61558

Approvals

ENEC 10; UL recognised component

//media.rs-online.com/t_line/L201568-10.gif

Approvals

VDE; UL

Standards

EN 61558

Specifications
Attribute Value
Secondary Voltage Rating 9V ac
Power Rating 0.35VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 22mm
Width 15mm
Depth 22.7mm
Dimensions 22 x 15 x 22.7mm
Weight 24g
Mounting Type Through Hole
Maximum Temperature +70°C
Temporarily out of stock - back order for despatch when stock is available
Price (ex. GST) Each
$ 7.99
(exc. GST)
$ 8.79
(inc. GST)
units
Per unit
1 - 9
$7.99
10 - 24
$7.70
25 - 49
$7.31
50 - 99
$7.05
100 +
$6.87
Packaging Options:
Related Products
ABT7PDU series transformers This range of covered (up ...
Description:
ABT7PDU series transformers This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double windingSecondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or ...
Description:
Type UI 39 - 10 VA → 30 VA Secondary voltages are nominal load voltages on resistive loadsOnly the pins indicated on the wiring diagram "physically" exist. Standards IEC 742, VDE 0551, SEV 1003 Approvals UL 506. Secondary voltages are ...
Description:
Type EI 30 - 1 VA → 23 VA series 44000 transformers From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and ...
PCB Mounting Low Profile 115 / 230Vac Primary ...
Description:
PCB Mounting Low Profile 115 / 230Vac Primary Twin 115Vac. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double ...