9V ac 2 Output Through Hole PCB Transformer, 1.5VA

  • RS Stock No. 173-9664
  • Mfr. Part No. 44092
  • Manufacturer Myrra
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): FR
Product Details

Type EI 30 - 1 VA → 2.3 VA series 44000 transformers

From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable.

Features and Benefits:

• Professional safety transformers with insulation above 4000V.
• For installation on printed circuit boards (according to European grid).
• Coupling in series or parallel.
• Vacuum-filled with resin to ensure materials withstand aging.
• Unit and 100% control on automated line.
• Secondary voltages are nominal load voltages on resistive loads.

Standards

UL 94-V0; VDE 0551; IEC 742

Approvals

UL, VDE

Encapsulated – Toroidal

Note

Fixing screws not provided

Specifications
Attribute Value
Secondary Voltage Rating 9V ac
Power Rating 1.5VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 32.6mm
Width 27.6mm
Depth 24.3mm
Dimensions 32.6 x 27.6 x 24.3mm
Weight 80g
Mounting Type Through Hole
Maximum Temperature +70°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
1 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 5.15
(exc. GST)
$ 5.67
(inc. GST)
units
Per unit
1 - 24
$5.15
25 - 49
$5.04
50 - 99
$4.78
100 - 249
$4.64
250 +
$4.54
Related Products
Fully shrouded bobbins Extra pins for secure board ...
Description:
Fully shrouded bobbins Extra pins for secure board mounting100% electrical and flash tested Tested in accordance with BS3535 and EN 60 742
Dual 115Vac. 50 to 60Hz primary Twin secondary ...
Description:
Dual 115Vac. 50 to 60Hz primary Twin secondary windings for series or parallel connection AVB series are inherently short circuit proof compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins100% electrical and flash ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loadsOnly the pins indicated on the wiring diagram "physically" exist.
Single and twin secondary windings for series or ...
Description:
Single and twin secondary windings for series or parallel connection Vacuum resin moulded to UL94-V0 rating Low inter-winding capacitance Low radiated noise100% electrical and flash tested Extra fixing points for secure board mounting (25 VA and 36 VA)