9V ac 1 Output Through Hole PCB Transformer, 1VA

  • RS Stock No. 173-8790
  • Mfr. Part No. 45002
  • Manufacturer Myrra
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): FR
Product Details

Type WUD 21 x 6.5 → 1 VA transformers

Secondary voltages are nominal load voltages on resistive loads.
Only the pins indicated on the wiring diagram "physically" exist.

Technical specifications
Primary voltage: 1 x 230 V
Pins - primary:  2 → 12
- secondary:  5 → 7
ref. Stock Secondary Secondary
Myrra no. voltage (V) current (mA)
45001 173-8784 6 160
45002 173-8790 9 111
45003 173-8807 12 83
45004 173-8813 15 67
45005 173-8829 18 56
45006 173-8841 24 42

Standards

IEC 742, VDE 0551, SEV 1003

Approvals

UL 506

//media.rs-online.com/t_line/LF173878-10.gif

Encapsulated – Toroidal

Maximum Operating Temperature +60°C
Primary – Secondary Test Voltage 4 kV
UL Recognised for Insulation Class A +105°C
Meets All Requirements of Class E +120°C
Pin Length x Diameter 1 x 0.5 mm

Note

Fixing screws not provided

Specifications
Attribute Value
Secondary Voltage Rating 9V ac
Power Rating 1VA
Primary Voltage Rating 230V ac
Number of Outputs 1
Length 34mm
Width 31mm
Depth 15mm
Dimensions 34 x 31 x 15mm
Weight 50g
Mounting Type Through Hole
Maximum Temperature +70°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
67 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 9.89
(exc. GST)
$ 10.88
(inc. GST)
units
Per unit
1 - 24
$9.89
25 - 49
$9.64
50 - 99
$9.18
100 - 249
$8.91
250 +
$8.69
Related Products
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connectionTwin secondary windings for series or parallel connectionLow profile compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedLow inter-winding ...
From Myyra, the 44000 Series of type EI ...
Description:
From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable. • Professional ...
Dual 115Va.c. 50 to 60Hz primaryTwin secondary windings ...
Description:
Dual 115Va.c. 50 to 60Hz primaryTwin secondary windings for series or parallel connection AVB series are inherently short circuit proof compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedHigh efficiency and ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...