1 x 9V ac 1 Output PCB Mount PCB Transformer, 2.8VA

  • RS Stock No. 121-3832
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

RS Pro PCB Standard Transformers

RS Pro PCB Standard transformers are low voltage mains transformers with a single 230 VAC 50/60Hz primary winding
These transformers have secondary windings suitable for series/ parallel connection to give a wide range of current options. They are 100% electric and flash tested. Double section bobbin, high efficiency and low temperature rise. These RS Pro transformers have low interwinding capacity and low radiated noise.

Specifications
Attribute Value
Secondary Voltage Rating 1 x 9V ac
Power Rating 2.8VA
Primary Voltage Rating 230V ac
Number of Outputs 1
Length 32.5mm
Width 27.5mm
Depth 34.5mm
Dimensions 32.5 x 27.5 x 34.5mm
Weight 140g
Mounting Type PCB Mount
Maximum Temperature +130°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
5 : Next working day (AU stock)
305 : 7 working days (Global stock)
Price (ex. GST) Each
$ 7.85
(exc. GST)
$ 8.63
(inc. GST)
units
Per unit
1 - 9
$7.85
10 +
$7.56
Related Products
ABT7ESM0 series economic transformer This range of single-phase ...
Description:
ABT7ESM0 series economic transformer This range of single-phase single-winding safety and isolation transformer is primarily designed for use in repetitive applicationsABT 7 series transformers provide enhanced electrical isolation between the mains supply and the application. The whole range features an ...
ABL 6TS safety transformers Single-phase single-winding safety and ...
Description:
ABL 6TS safety transformers Single-phase single-winding safety and isolation transformersAble to supply higher powers on occasion.Feature a panel display to reduce ESD. Screw termination.Plate mounting. Standards IEC 61558-2-6 , EN61558-2-6. Chassis mounting frame construction low voltage mains transformers with a ...
Description:
Type UI 39 - 10 VA → 30 VA Secondary voltages are nominal load voltages on resistive loadsOnly the pins indicated on the wiring diagram "physically" exist. Standards IEC 742, VDE 0551, SEV 1003 Approvals UL 506. Secondary voltages are ...
PCB Mounting Low Profile 115 / 230Vac Primary ...
Description:
PCB Mounting Low Profile 115 / 230Vac Primary Twin 115Vac. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double ...