15V ac 2 Output Through Hole PCB Transformer, 20VA

  • RS Stock No. 504-763
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

PCB Mounting, Flame Retardant Transformer with Thermal Fuse

Thermal fuse in primary providing overload and short circuit protection
Flame retardant materials to UL94-V0
Fully shrouded windings
Extra pins for secure board mounting
Designed and tested in accordance with EN 61558 (EN 60742) EN 60950

Construction Class 2
Insulation Class B (130°C)
Isolation (Primary to Secondary) 4.8 kV rms
Isolation (Windings to core) 2.4 kV rms
Pin Length x Diameter 5 x 1 mm
Maximum Winding Temperature Rise +55°C
Input Voltage 230 Vac
//media.rs-online.com/t_line/L805502-01.gif

Approvals

8888

Standards

EN 61558 (EN 60742); EN 60950

Open Frame - Laminated

PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section metric bobbin construction
Full varnish impregnation

Specifications
Attribute Value
Secondary Voltage Rating 15V ac
Power Rating 20VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 60mm
Width 54mm
Depth 42mm
Dimensions 60 x 54 x 42mm
Weight 500g
Mounting Type Through Hole
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
42 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 14.20
(exc. GST)
$ 15.62
(inc. GST)
units
Per unit
1 - 9
$14.20
10 - 24
$13.49
25 - 49
$12.08
50 +
$11.37
Related Products
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz ...
Description:
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range ...
RS Pro PCB Standard transformers are low voltage ...
Description:
RS Pro PCB Standard transformers are low voltage mains transformers with a single 230 VAC 50/60Hz primary windingThese transformers have secondary windings suitable for series/ parallel connection to give a wide range of current options. They are 100% electric and ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...
High-quality open style toroidal transformers with a single ...
Description:
High-quality open style toroidal transformers with a single 230 Vac 50/60 Hz primary winding. Twin secondary windings may be connected in series or parallel or used independently. Small size and low weight compared with traditional stacked lamination typesExtremely low level ...