9V ac 2 Output Through Hole PCB Transformer, 12VA

  • RS Stock No. 504-723
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

PCB Mounting, Flame Retardant Transformer with Thermal Fuse

Thermal fuse in primary providing overload and short circuit protectionFlame retardant materials to UL94-V0Fully shrouded windingsExtra pins for secure board mountingDesigned and tested in accordance with EN 61558 (EN 60742) EN 60950

//media.rs-online.com/t_line/L805502-01.gif

Approvals

8888

Standards

EN 61558 (EN 60742); EN 60950

Open Frame - Laminated

PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section metric bobbin constructionFull varnish impregnation

Specifications
Attribute Value
Secondary Voltage Rating 9V ac
Power Rating 12VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 54mm
Width 45mm
Depth 41mm
Dimensions 54 x 45 x 41mm
Weight 400g
Mounting Type Through Hole
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
8 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 16.15
(exc. GST)
$ 17.77
(inc. GST)
units
Per unit
1 - 9
$16.15
10 - 24
$15.34
25 - 49
$13.72
50 - 99
$12.93
100 +
$12.29
Related Products
Twin 115Vac. 50 to 60Hz primary windings for ...
Description:
Twin 115Vac. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins100% electrical and ...
230Vac. 50 to 60Hz primary Single or twin ...
Description:
230Vac. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loadsOnly the pins indicated on the wiring diagram "physically" exist.
From Myyra, the 44000 Series of type EI ...
Description:
From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable. • Professional ...